SECTION 5 − ELECTRICAL DIAGRAMS
Product
Input Votage
(3-Phase)
220 VAC
230 VAC
400 VAC
CST 280
CST 280
440 VAC
460 VAC
575 VAC
* Full 280 amperes output from power source may cause rack line fuses to blow. Reduce output to 235 amperes.
** Full 280 amperes output from power source may cause rack line fuses to blow. Reduce output to 245 amperes.
{ Rack is supplied with 25 ampere fuses. No fuse kit is available.
Figure 4-1. Circuit Diagram For Control Panel In Racks
Table 4-1. Fuse Size Requirements
Amperage Input
Recommended
At Rated Load
Line Fise Size
Output, 50/60
(Amps)
Hz
34.2
33.5
30**
19.7
18.1
17.4
14.3
Miller Fuse Kit
Part No.
(12 pcs)
30*
195 349
195 349
25
{
25
{
25
{
20
195 348
208 333
Individual Fuse
Bussman Fuse
Part No.
Part No.
199 795
KTK-R-30
199 795
KTK-R-30
220 513
KTK-R-25
220 513
KTK-R-25
220 513
KTK-R-25
212 541
KTK-R-20