Air-to-water heat pump:
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
Parameters shall be declared for
Parameters shall be declared for
Item
Rated heat output (*)
Declared capacity for heating for part load at indoor temperature 20°C
and outdoor temperature Tj
Tj = – 7 °C
Tj = +2 °C
Tj = +7 °C
Tj = +12 °C
Tj =bivalent temperature
Tj = operation limit temperature
Tj = – 15 °C (if TOL < – 20 °C)
Bivalent temperature
Cycling interval capacity for heating
Degradation co-efficient (**)
Power consumption in modes other
than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Other items
Capacity control
Sound power level, indoors/outdoors
Annual energy consumption
Contact details
Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd.
No. 218, Qianwangang Road, Economic and Technological Development Zone, Qingdao, China
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for
heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Technical parameters
Outdoor unit: AHW-160HC(E)DS1
Indoor unit:
AHM-160HC(E)DSAA
yes
no
no
no
yes
no
Medium temperature application.
average climate conditions.
Symbol
Value
Unit
Prated
12.5
kW
Pdh
11.10
kW
Pdh
6.57
kW
Pdh
4.30
kW
Pdh
3.76
kW
Pdh
11.10
kW
Pdh
12.03
kW
Pdh
-
kW
Tbiv
-7
°C
Pcych
-
kW
Cdh
0.9
-
0.005
kW
POFF
0.009
kW
PTO
0.005
kW
PSB
0
kW
PCK
variable
44/67
dB
LWA
7900
kWh
QHE
45
TECHNICAL PARAMETERS
Item
Seasonal space heating energy efficiency ηs
Declared coefficient of performance or primary energy ratio for
part load at indoor temperature 20 °C and outdoor temperature Tj
Tj = – 7 °C
Tj = +2 °C
Tj = +7 °C
Tj = +12 °C
Tj =bivalent temperature
Tj = operation limit temperature
Tj = – 15 °C (if TOL < – 20 °C)
Operation limit temperature
Cycling interval efficiency
Heating water operating limit temperature WTOL
Supplementary heater
Rated heat output (*)
Type of energy input
Rated air flow rate, outdoors
Symbol
Value
Unit
128
%
COPd
2.24
-
COPd
3.06
-
COPd
4.33
-
COPd
5.75
-
COPd
2.24
-
COPd
1.89
-
COPd
-
-
TOL
-10
°C
COPcyc
-
-
-
°C
Psup
0.5
kW
Electric
3
4200
m
/h