9.6

Troubleshooting and fault clearance

This section contains information on safe troubleshooting of the machine.
The following table gives an overview of malfunctions and measures to remedy them.
Malfunction
System does not
work
System does not
work
Cleaning at the filter
does not work
Compressor does
not run
Compressor does
not run
Dust extractor ME 12
Original operating instructions
Possible cause
Power source not in order
Components in the system
defective
Plug on the solenoid valve
has come loose
Switch on compressor not
switched on
Compressor plug has come
loose
Maintenance
Remedy
Have the power source repaired by
a specialist
Have the system repaired by
deconta or a workshop authorised
by deconta.
Reconnect the plug
Open the compressor maintenance
flap (on the front) and switch on the
compressor switch.
Open the compressor maintenance
flap (on the front) and reconnect
the plug.
38 from 41
Version 2