Page 1
Instructions for Use TID0102-HDL DVI Splitter and Converter Important Please read the safety information and all information delivered with the product carefully to familiarize yourself with safe and effective usage.
Use of EIZO products WARNING EIZO products may only be used for the applications described in the catalog and in the relevant tech- nical documentation. If products and components from other manufacturers are used, these must be recommended or approved by EIZO. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
(HDL) signals and transmit them to a maximum of two full HD monitors at a maximum distance of 70 m. The TID0102-HDL can be used in the same areas as the LMM0804, usually in the 19” rack or as a desktop device in the medical environment.
2 Safety information 2.1 General safety instructions Correct and safe operation of EIZO devices assume professional transport, storage, installa- tion, and connection, as well as careful operation and service. The devices may only be used for applications for which they are intended.
Page 7
Connection in China Only use power cables approved for China. These power cables are identified by the labels "CCC" or "CQC". Observe the country-specific regulations Observe all regulations of the country in which the device is used. TID0102-HDL Instructions for Use, 05/2019...
Page 8
If the device is brought into a room with a higher or rising temperature, condensed water will form in and on the device. Do not switch on the device until the condensed water has evaporated. Other- wise, the device could be damaged. TID0102-HDL Instructions for Use, 05/2019...
Page 9
Note that monitors can fail as a result of aging, and that image properties such as brightness, con- trast,and color value can change. Do not touch the monitor screen Due to mechanical pressure or electrostatic discharges, touching the screen can result in brief distur- bances to the image. TID0102-HDL Instructions for Use, 05/2019...
If the device is connected to line power through the external power supply unit, the device must be connected to a protective ground conductor. This is the only way to ensure that the touch leakage current in a first fault event does not exceed 500 µA. TID0102-HDL Instructions for Use, 05/2019...
TID0102-HDL 6GF60102BA01 The TID0102-HDL was developed specifically for splitting and transmitting DVI signals. The TID0102-HDL can be used as an enhancement for the Large Monitor Manager LMM0804 (order number 6GF60301AB10) or in standalone mode. Components The following components are included in the scope of delivery: •...
3.2 Features Variable image output during signal splitting The TID0102-HDL can split the specific DVI dual link output signal of the LMM0804 into two standardized DVI single link signals and two high definition video links (HDL) signals. Alternatively, the TID0102-HDL can split the DVI single link signal of any video source into two DVI single link and two HDL signals.
LMM0804 operation. Use of the TID0102 as a DVI splitter with the LMM0804 Note When operating the TID0102-HDL at a LMM0804 the DIP switch 5 on the front should be mandatory on "DVI 1 or HDL 1" (OFF). •...
Page 14
Ethernet cables are used to transmit the HDL signals. The recommended Ethernet cable category is CAT6 or better. • The power supply unit is included in the scope of delivery. • The image content on the monitors can be switched using the DIP switches on the TID0102. TID0102-HDL Instructions for Use, 05/2019...
Page 15
Connection to any video source with DVI single link output, such as a PC graphics card. • Maximum of four configurable video signals for full HD monitors. • Transmission of maximum two video signals over a distance of up to 70 m using HDL technology on HDL-compatible monitors. TID0102-HDL Instructions for Use, 05/2019...
This can take several hours. 4.2 Positioning as a desktop device The TID0102-HDL can be set up as a desktop device. Make sure the surface where it is to be placed is solid and even. Four adhesive feet for positioning are included in the scope of delivery. They can be at- tached to the underside of the device.
Setup and installation 4.3 Installation on table or wall 4.3 Installation on table or wall The TID0102-HDL can be attached to the table or wall using the mounting brackets pro- vided. Make sure the surface is solid and even. CAUTION Tightening torque Excessive tightening torque when installing the device can damage the mounting surface.
Screw length 8 mm Maximum tightening torque 3 Nm Procedure 1. Attach the two holders on the back of the TID0102-HDL using the four M3 screws pro- vided. NOTICE: Comply with the maximum tightening torque of the screws. Holder TID0102-HDL Instructions for Use, 05/2019...
Page 19
Setup and installation 4.4 Installing in a rack 2. Using the two M4 screws provided, install the TID0102-HDL vertically in the rack. Note: Follow the safety information for installing devices in the rack. CAUTION Installing devices in the rack • To prevent the rack from tipping over, arrange the devices so that the center of gravity of the rack and devices is below the center of the rack.
CAUTION Changes to device Do not make any mechanical or electric changes to the device. EIZO GmbH is not liable for changes made to the device. CAUTION Shielding measures Follow all shielding measures in accordance with local EMC directives. If these guidelines are not observed, device malfunction may result.
TID0102. Rear connectors Connectors Type Function Config 2 DIP switch Enhanced configuration of the TID0102. Power 2 pin power supply plug Connection of a power supply. Protective Connection of an additional protective conductor. conductor TID0102-HDL Instructions for Use, 05/2019...
5.3.1 Connecting to the LMM0804 To connect the TID0102-HDL to the LMM0804 proceed as follows: 1. Connect the "DVI IN" input of the TID0102-HDL to the "Monitor 1" or "Monitor 2" output of the LMM0804 using the dual link cable provided.
Depending on the application, a power supply via an external 12 V power supply unit is required. Connect the power supply unit to the TID0102-HDL as follows: 1. Connect the power supply unit to the power connector on the back of the TID0102.
When the DIP switch is up, it corresponds to “ON” in the following figure. When the DIP switch is down, it corresponds to “OFF”. Note When operating the TID0102-HDL at a LMM0804 the DIP switch 5 on the front should be mandatory on "DVI 1 or HDL 1" (OFF). TID0102-HDL...
Configuring 6.2 Advanced settings 6.2 Advanced settings The TID0102-HDL has DIP switches on its back for the following advanced settings: • HPD (Hot Plug Detect) and determines whether a signal is applied to the corresponding output when a monitor is removed.
Operation 7.1 Operator controls 7 Operation 7.1 Operator controls The TID0102-HDL has no operating elements or on and off switches. The TID0102-HDL is ready for operation once connected. The DIP switches are used exclusively for configuring. TID0102-HDL Instructions for Use, 05/2019...
Perform Dismozon pur Standard household washing- denk mit Fairy Ultra, Pril, Palmolive up liquid Pyridine derivatives Activ spray, undiluted Water Tap water Distilled water Spray disinfectant Nocolyse Test conditions Contact test accord- ing to MFR890/009 TID0102-HDL Instructions for Use, 05/2019...
Petroleum spirit close to boil- Petroleum ether Note Cleaning other components Information on cleaning or disinfection of other system components can be obtained from the respective instructions for use. 8.2 Maintenance The TID0102-HDL is maintenance free. TID0102-HDL Instructions for Use, 05/2019...
LED 1: Indicates whether a signal source is connected (green) or not (orange). • LED 2: Indicates whether the TID0102-HDL is in software mode (green) or hardware mode (orange) or whether the TID0102-HDL is being supplied insufficient current (red). Status...
WERI Part No. 691 361 100 002 or Dinkle EC350V-XXP Socket: Dinkle ECH350R-02PTHT The socket is located on the back. 10.2 Power supply TID0102-HDL Rated voltage 12 V Current consumption 0.4 - 0.7 A Maximum current consumption 8.4 W...
9 - 150 Hz at 2 m/s², 5 cycles each per x/y/z-axis, 1 octave / minute Shock According to TR60721-4-3, Kl. 3M3: 50 m/s , 6 ms, half sine wave Per 3 shocks in each direction and +/- Total shocks 18 TID0102-HDL Instructions for Use, 05/2019...
This product has been assigned a CE marking in compliance with the stipulations of EU di- rectives 2014/30/EU and 2011/65/EU. Safety standards IEC60950-1:2005 (2nd Edition) CAN/CSA - C22.2. No. 601.1-M90 CAN/CSA - C22.2. No. 60601-1:08 Protection class Protection class I Degree of protection IP20 in accordance with DIN 40050 TID0102-HDL Instructions for Use, 05/2019...
EN 61000-4-8 (2010-02) Short-term voltage dips and power interruptions IEC 61000-4-11 (2010-08-01) EN 61000-4-11 (2004-08) Line reaction to harmonics IEC 61000-3-2 (2014-05-01) EN 61000-3-2 (2014-08-01) Line reaction to voltage fluctuations EN 61000-3-3 (20013-05-01) EN 61000-3-3 (2014-08-01) TID0102-HDL Instructions for Use, 05/2019...
Dimension drawings 11.1 View from front and back 11 Dimension drawings All dimensions in mm 11.1 View from front and back TID0102-HDL Instructions for Use, 05/2019...
Spare parts / accessories 12.1 Accessories 12 Spare parts / accessories 12.1 Accessories Accessories Order number Description 19" Rack Enclosure 6GF69201BA00 Enclosure for up to two TID0102 devices for horizontal installation in 19" racks. TID0102-HDL Instructions for Use, 05/2019...
13 Appendix 13.1 Guidelines and manufacturer's declaration – electromagnetic emissions The TID0102-HDL is intended for use in the environment specified below. The customer or the user of the device should ensure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –...
Comply with all local requirements and laws pertaining to the disposal of devices. The device is in compliance with directive 2011/65/EU for limiting the use of specific haz- ardous materials in electric and electronic devices. 13.7 Contact Support during installation and for technical questions www.eizo-or.com TID0102-HDL Instructions for Use, 05/2019...
13.8 Trademarks 13.8 Trademarks The EIZO Logo is a registered trademark of EIZO Corporation in Japan and other countries. EIZO is a registered trademark of EIZO Corporation in Japan and other countries. RadiForce is a registered trademark of EIZO Corporation in Japan and other countries.