Download Print this page

Environment & Reliability; Crt Characteristics - Mitsubishi Electric Diamond View 1995SL Service Manual

Crt monitor

Advertisement

1995SL CRT Monitor Service Guide
2.ENVIRONMENT & RELIABILITY
Operation Temp./Humidity
Non- Operation Temp./Humi.
Altitude
Vibration
Drop (With packing)
Electrostatic Discharge
Acoustical Noise
Power Line Transient
MTBF Demonstration
MTBF Prediction
CRT Life

3.CRT CHARACTERISTICS

CRT Vender
Technology
Coating
Dot pitch
Phosphor
Light transmittance
Viewable size
Deflection angle
Blemishes and scratches
Condition
Operating condition
Non-operating condition
Package, Non-Operating
Un-package, Non-
Operating
PKG. 18.2~27.2 Kg
IEC801-2 standard
IEC801-4,IEC1000-4-4 Coupling clamp 0 ~ 4KV
IEC1000-4-5 (Surge)
IEC1000-4-12 (100KHz
ringwave)
90% confidence level
MIL-217F
78% degradation
Philips
Chapter 1 Engineering Specification
Spec
+5 ~ +40℃/ 20~90% R.H.
-20~ +60℃/ 10~90% R.H.
0~3048m (10,000ft)
0~12,192m (40,000ft)
5~26.6Hz/0.6G
50~500 Hz/1.5G
5~100/0.015g2/Hz
Drop Height 61 cm
Contact:8KV, Air:15KV
< 40 dB/A
Common:2KV,Differential:1KV
Common:3KV,Differential:1KV
> 200,000 Hrs
> 40,000 Hrs
> 10000 Hrs
Spec
Shadow mask
FST
Anti-glare/Anti-
static/Anti-reflection
0.26mm
P22
52.3%
>18"
95 deg
1 trio missing,as approval
Remark
OK
N.A
Non-condensing
Non-condensing
Without packing
With packing
26.6~50Hz/1.5G
100~200/-6db/oct
200~0.038g2/Hz
0.5~8KV tip table no
blanking
Excluding the CRT
Remark
OK
N.A
see table 2
5

Advertisement

loading