1995SL CRT Monitor Service Guide
9. Clear all of user mode data
After finishing all factory setting , select "Reset to default "at MENU 1 then press enter.
10. Geometry Specification
ITEM
1
2
3
4
5
6
7
8
9
11. Power Saving Function Check
a. Input mode 31KHz (VGA400 640 X 400) with full-white pattern.
b. Press both contrast and brightness keys to maximum position.
[Standby Mode]
c. Remove the horizontal sync signal from input, the unit will go into "Standby" mode.
The picture will disappear, and the LED indicator is amber. The power consumption
should be less than 15W.
[Suspend Mode]
d. Remove vertical sync signal from the input, the unit will go into "Suspend" mode.
The picture will disappear, and the LED indicator is amber (blinking). The power
consumption should be less than 5W.
[Off Mode]
e. Remove both syncs from input, the unit will go into "Off" mode.
The picture will disappear, and the LED indicator is amber (blinking). The power
consumption should be less than 5W in this case.
f. Input H-sync and V-sync signals in case c, d and e, the unit will recover to normal
state, and the LED indicator is green.
[Override Mode]
DESCRIPTION
HORI SIZE
VERT SIZE
SIDE PIN
TOP/BOTTOM PIN
SIDE BARREL
TOP/BOTTOM BARREL
TRAPEZOID
VIDEO OFFSET
PARALLELOGRAM
Chapter 3 Alignment Procedure
SPECIFICATION
350 ± 4 mm
262 ± 4 mm
≦ 1.8 mm
≦ 1.35 mm
≦ 1.8 mm
≦ 1.35 mm
≦ 3.0 mm
≦ 4.0 mm
≦ 3.5 mm