Gardner Denver EAQ99S Operating And Service Manual page 29

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

STARTING THE UNIT - Observe the following starting procedures.
Unit Cold - If the unit is a water-cooled heat exchanger model, open any manual water inlet valves wide
open. Start the unit by pushing either the "CONSTANT RUN" button or one of the "AUTO" buttons. Since
the unit is equipped with a minimum (4.5 bar) pressure discharge valve, no special procedure to maintain
unit reservoir pressure is required.
Unit Hot - No warm-up period is required. If the unit is a water-cooled heat exchanger model, open any
manual water inlet valves wide open. Start the unit by pushing either the "CONSTANT RUN" button or
one of the "AUTO" buttons.
DAILY CHECK - Refer to Section 8, "Maintenance Schedule.
STOPPING THE UNIT - Press "STOP-RESET" button. The oil reservoir will automatically blow down as
the motor stops. If the unit is a water-cooled heat exchanger type, close any manual water inlet valves.
13-10-616