Gardner Denver EAQ99S Operating And Service Manual page 26

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

MOTOR LUBRICATION - Long time satisfactory operation of an electric
motor depends in large measure on proper lubrication of the bearings. The
following charts show recommended grease qualities and regreasing
intervals for ball bearing motors. For additional information refer to the
motor manufacturer's instructions. The following procedure should be used
in regreasing:
Stop the unit.
1.
2.
Disconnect, lockout and tagout the unit from the power supply.
3.
Remove the relief plug and free hole of hardened grease.
4.
Wipe lubrication fitting clean and add grease with a hand-operated grease gun.
5.
Leave the relief plug temporarily off. Reconnect the unit and run for about 20 minutes to expel the
excess grease.
Stop the unit. Replace the relief plug
6.
Restart the unit.
7.
Rotating machinery can cause injury or death. Open main disconnect, lockout
and tagout power supply to starter before working on the electric motor.
ELECTRIC MOTOR GREASE RECOMMENDATIONS (-30° C to 50° C)
MANUFACTURER
CHEVRON
SHELL
EXXON
EXXON
Type of
Service
Standard
One or Two Shift Operation
Severe
Continuous Operation
Dirty Locations, High Ambient
Very Severe
Temperature
.
ELECTRIC MOTOR REGREASING INTERVAL
Typical
Up to 150 HP (112 kW)
Above 150 HP (112 kW)
Up to 150 HP (112 kW)
Above 150 HP (112 kW)
Up to 150 HP (112 kW)
Above 150 HP (112 kW)
13-10-616
TRADE NAME
SRI #2
DOLIUM R
UNIREX #2
POLYREX
Rating
Page 25
Relubrication Interval
18 Months
12 Months
9 Months
6 Months
4 Months
2 Months

Advertisement