Figure 4-3 - Inlet Valve; Figure 4-4 - Shuttle Valve - Gardner Denver EAQ99S Operating And Service Manual

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

208EDM797-A
(Ref. Drawing)
Solenoid Valves IVC and IVO - These valves control position of the inlet valve in response to signals
from the "AutoSentry". With both valves de-energized, the normally open IVC valve allows control
pressure to the inlet piston to close the valve. If IVC only is energized, the inlet valve is held in its current
position. If both valves are energized, control pressure is relieved from the inlet piston to allow the valve
to open.
Pressure Regulator - The pressure regulator is used to supply a constant and low control pressure to
prevent damage to the inlet valve from "slamming." The regulator should be set for 1.7 bar to 2.1 bar.
Shuttle Valve (Figure 4-4) - Also known as a double check valve, the shuttle valve is a device which will
take two (2) supply signals and allow the one with the highest pressure to pass through. The shuttle
valve is used to provide control air pressure from either the reservoir or plant air system, as required
during different operating conditions.
Figure 4-3 – INLET VALVE
Figure 4-4 – SHUTTLE VALVE
13-10-616
Page 32