Checking The Hydraulic Oil Level - Fayat Group DYNAPAX DRP45DX Operating Instruction, Maintenance Instruction

Reversible plate
Table of Contents

Advertisement

Maintenance – Annually / every 250 operating hours

8.9.7 Checking the hydraulic oil level

Fig. 99
Fig. 100
Fig. 101
Fill in hydraulic oil, bleed the
system
90
Protective equipment:
1.
Park the machine safely
in secured condition' on page 59.
2.
Adjust the steering rod using the height adjustment so that
the area with the filler screw is horizontal.
3.
Unscrew the filler screw.
B-695-0143
4.
Press the handle forward against the stop and secure it using
suitable means.
B-692-0070
5.
The oil level must reach the mark on the steering rod head; if
necessary, fill in hydraulic oil.
Mark: approx. 40 mm (1.6 in) below the filler opening
B-695-0141
NOTICE!
Components may get damaged!
DRP45DX
n
Working clothes
n
Safety shoes
n
Protective gloves
Ä Chapter 6.4 'Parking the machine
Use only oil of the permitted specification
Ä Chapter 8.3.4 'Hydraulic oil' on page 70.