5.5

Caratteristiche Tecniche - Techincal Features TT Standard/Advanced

Alimentazione
Potenza assorbita (P1)
Potenza max.
Elettropompa (P2)
(400 Vac trifase)
Max. corrente di fase
Frequenza d'uscita
Tempo di acceleraz.
Tempo di deceleraz.
Display
Posiz. Montaggio HCW
Posiz. Montaggio HCA
Pressione impostabile
Sovrappressione Max
(versione HCW)
Temperatura ambiente di
funzionamento
Grado di protezione
Ingresso/uscita per modelli
HCW
Dim.HCW (3-5.5hp) h/l/p
Dim.HCA (3-5.5hp) h/l/p
Dim.HCA (7.5hp-15hp) h/l/p
Peso
HCW (3-5.5hp)
Peso
HCA (3-5.5hp)
Peso
HCA (7.5hp)
Peso
HCA (10hp)
Peso
HCA (15hp)
400 Vac 50/60 Hz
(da 300 a 450 Vac)
Vers. HC 3hp = 3,3 KW Max
Vers. HC 5,5hp = 6 KW Max
Vers. HC 7,5hp = 8 KW Max
Vers. HC 10hp = 10 KW Max
Vers. HC 15hp = 14 KW Max
Vers. HC 3hp = 2,2 kW
Vers. HC 5,5hp = 4 KW
Vers.HC 7,5hp= 5,5 KW
Vers.HC 10hp= 7,5 KW
Vers.HC 15hp= 11 KW
Vers.HC 3hp = 6A
Vers.HC 5,5hp = 11A
Vers.HC 7,5hp= 15A
Vers.HC 10hp= 18A
Vers.HC 15hp= 25A
10 ÷ 100 Hz
1 ÷ 10 sec
1 ÷ 10 sec
LCD 2 righe x 16 caratteri
Qualsiasi – su tubazione
Verticale - in aria libera
0,3 ÷ 7,5 Bar (vers. HCW)
0,3 ÷ 10 Bar (vers. HCA con
sensore standard)
0,3 ÷ 25 Bar (vers. HCA con
sensore opzionale)
12 Bar
5°C ÷ +40 °C
Vedi etichetta prodotto
1" ¼ femmina
170/190/360 mm.
190/260/400 mm.
255/285/400 mm.
4 Kg
6 Kg
11 Kg
11,5 Kg
12 Kg
Three phase power
Absorbed power (P1)
Electro-pump max. Power
(400Vac three Phase)
(P2)
Max. Phase current
Output frequency
Acceleration time
Deceleration time.
Display
HCW assembly pos.
HCA assembly pos.
Pressure to be set
Max overpressure
For HCW models
Operating ambient
Temperature
Protection category
Input/output for HCW
models
Dim.HCW(3-5.5hp) h/l/p
Dim.HCA(3-5.5hp) h/l/p
Dim.HCA(7.5hp-15hp) h/l/p
Weight
HCW (3-5.5hp)
Weight
HCA (3-5.5hp)
Weight
HCA (7.5hp)
Weight
HCA (10hp)
Weight
HCA (15hp)
400 Vac 50/60 Hz
(from 300 to 450 Vac)
Vers.HC 3hp = 3,3 KW Max
Vers.HC 5,5hp = 6 KW Max
Vers.HC 7,5hp = 8 KW Max
Vers.HC 10hp = 10 KW Max
Vers.HC 15hp = 14 KW Max
Vers.HC 3hp = 2,2 KW Max
Vers.HC 5,5hp = 4 KW Max
Vers.HC 7,5hp = 5,5 KW Max
Vers.HC 10hp= 7,5 KW
Vers.HC 15hp= 11 KW
Vers.HC 3hp = 6A
Vers.HC 5,5hp = 11A
Vers.HC 7,5hp = 15A
Vers.HC 10hp= 18A
Vers.HC 15hp= 25A
10 ÷ 100 Hz
1 ÷ 10 sec
1 ÷ 10 sec
LCD 2 lines x 16 characters
Any on piping
Vertical - in free air
0,3 ÷ 7,5 Bar (vers. HCW)
0,3 ÷ 10 Bar (vers. HCA con
sensore standard)
0,3 ÷ 25 Bar (vers. HCA con
sensore opzionale)
12 Bar
5°C ÷ +40 °C
In Label product
1" ¼ female
170/190/360 mm.
190/260/400 mm.
255/285/400mm.
4 Kg
6 Kg
11 Kg
11,5 Kg
12 Kg
19