Sony CCD-F35 Service Manual page 159

Video camera recorder
Table of Contents

Advertisement

7-2-16.
Y Level Adjustment (CV-8 Board)
7-2-17.
White Clip Adjustment (CV-8 Board)
point array
Measurement Point
.
point array
Measuring Instrument | Oscilloscope
Measuring Instrument | Oscilloscope
'Adjustment Address _ | 18 (Y LEVEL)
Adjustment Address _| 17 (WHITE CLIP)
Specified Value
330 + 10mV
Adjustment method:
1) Set the adjustment address to 17 with the adjustment remote
commander, and make a note of the adjustment data for this
address.
2) Set the adjustment data to FF with the adjustment remote
commander.
ary 3 Center of white level
| 330 + 10 mV
Center of pedestal level
— Center of pedestal level
Fig. 7-22.
Specified Value
420 + 10 mV
Adjustment method:
1) Set the adjustment address to.17 with the adjustment remote
commander.
2) Change the adjustment data with the adjustment remote
commander to set the white clip level to 420 + 10 mV.
3)
Change the adjustment address to store the adjustment data
in the memory.
Approx. 3 usec
"
Ure
are
420 +10 mV
a
Center of black level
Fig. 7-23.
— 213 —

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ccd-f36Ccd-f280

Table of Contents