7-1-2.
Preparations
Note: Refer to "2, DISASSEMBLY" for details on removal of
aver ber,
the cabinet and various boards.
1) Connect the various devices for adjustment as shown in Fig.
73.
2) The EVF (electronic viewfinder) is needed for confirmation
of the white balance mode and shutter speed. This can
confirmed on the monitor screen by tuming on the data
screen (ON/OFF by $509 on VK-1 board). Remove CN901
on the CV-8 board when the EVF is not needed.
3) The mic amplifier (MA-31 board) is not needed. Remove
CN401 on the CO-2 board.
Lens standard surface
Imaging surface of CCD imager
(IC601 on CD-10 board)
Fig. 7-2.
Set to the adjustment mode by connecting the
in the CV-8 board check point array to
GND with a jumper wire after turning on the
power,
Main unit
Battery terminal
x
°
OO
CLI Vidco output
jack
x
Regulated
power supply
(6.5 + 0.1 Vde)
Oscilloscope
When an external trigger is needed for
measurement
using
an
oscilloscope,
connect Pin ® (HD) of CN802 on the CV-8
board to the EXT TRIG terminal of the
oscilloscope.
Cabinet L
Vectorscope
Color monitor
Adjustment remote commander
75Q
terminated
Fig. 7-3,
NO