4.3 Connection WTR 120 with M12 plug
4.4 Mechanical assembly
For adaptation in your process, only use the weld-in sockets and process
connections from promesstec. This is the only way we can promise you an op-
timal measuring point.
After installing the sensor, check the tightness of the measuring point
4.5 Electrical assembly
The electrical installation must be carried out in a de-energized state.
Connection with cable gland:
Insert the connection cable into the cable entry (screw connection). Be careful
not to damage the seal on the cable gland.
Connect the connecting cables according to your circuit task.
You can parameterize the device via the interface (DMU 100, KMU 100 or
KMUS 100 measuring transducer option).
Close the case and turn on the power.
Connection with M12 connector:
Screw the M12 socket onto the plug on the promesstec by hand
Sensor. Assembly is carried out without tools.
When installing the connection cable, ensure that it is firm and form-fitting
Connection of both components. The permissible tightening torque can be
found in the data sheet of the respective connection cable.