Fine Adjustment By Correction Potentiometer; Technical Specifications; Technical Data Dmu 100 - promesstec WTR 120 User Manual

Resistance thermometer
Table of Contents

Advertisement

5.3.2 Fine adjustment by correction potentiometer

As can be seen in the image above, the correction potentiometer is located on the
upper side of the KMUS. This can be used to fine-tune the output voltage. A seal
secures the potentiometer against accidental adjustment.
6.

Technical specifications

Protective fitting made of stainless steel 1.4571
Diameter 9 x 1 mm, other diameters on request
Process connection thread G 1/2"A, others on request
Operating temperature: -50 °C to +400 °C (extended ranges on request)
Deviation in operating temperature when using a transmitter

6.1 Technical data DMU 100

Operating temperature:
Operating voltage:
Current requirement:
Input:
Measuring range max.:
Measuring span min.:
Measuring deviation:
Output:
Sensor break:
Standard configuration:
Max. permissible load:
Display:
Orientation display:
Display digits:
Display range:
Configuration interface:
Electrical connection:
Configuration:
promesstec GmbH I Niedersachsenstraße 4 I D-48465 Schüttorf I Tel.:+49 (0)5923/ 90 229 0 I Fax:+49 (0)5923/ 90 229 29
-30 °C..+70 °C
UB = 10..35 V DC
7.3 mA (UB=24V) + 4..20mA output
PT1000 2-wire
-100°C..+650°C
10 K
<+-0.1% of the final value
4..20mA 3-wire (underflow 3.5mA, overflow
20.5mA)
21mA
4mA = -50°C, 20mA = 150°C
(wide temperature range can be parameterized)
Rmax = [(UB – 6V) / 0.021 A] Ω
high-resolution OLED display 0.96 inches
0° or 180°
4 digits
-99.9 to +999.9°C
USB Type C
6 screw terminals 1.5mm²
Commercially available USB C cable (no program-
ming adapter necessary)
Windows application for configuration ("pmt-Konfig-
Tool")
E-Mail: office@promesstec.com I Internet: www.promesstec.com
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wtr 120-5-b-1a3-kmuWtr 120-1-b-1a3-kmu

Table of Contents