6.2 Technical data KMU 100

Operating temperature:
Operating voltage:
Current requirement:
Input:
Measuring range max..
Measuring span min.:
Measuring deviation:
Output:
Sensor break:
Standard configuration.
Ambient temperature:
Electrical connection:
Configuration:

6.3 Technical data KMUS 100

Operating temperature:
Operating voltage:
Current requirement:
Input:
Measuring range:
Measuring deviation:
Output:
Sensor break:
Standard configuration:
Electrical connection:
Configuration:
promesstec GmbH I Niedersachsenstraße 4 I D-48465 Schüttorf I Tel.:+49 (0)5923/ 90 229 0 I Fax:+49 (0)5923/ 90 229 29
-40 °C..+85 °C
UB = 10..35VDC
4..20mA output
PT100 2, 3, 4 wire
-200°C..+650°C
10 K
<+-0.1% of the final value
4-20mA (underflow 3.5mA, overflow 20.5mA)
21mA
4mA = -50°C, 20mA = 150°C (wide temperature
range can be parameterized)
Operating temperature -40°C..85°C
6x screw terminals 1.5mm²
PXU01 programming adapter
Windows application for configuration ("PXU01")
-40 °C ..+85 °C
UB = 15..35 V DC
max. 10mA
PT100/PT1000 2, 3, 4 wire
12 measuring ranges, see page 3
<+-0.3% of measuring range
0..10V 3-wire
>10V
0V = -20°C, 10V = 150°C
5x terminal connection 1.5 mm²
DIP switch (12 different measuring ranges)
E-Mail: office@promesstec.com I Internet: www.promesstec.com