  • Page 1 User Manual C1 Pos Scale Rongta Technology (Xiamen) Group Co., Ltd. www.rongtatech.com V1.0...
  • Page 2: Table Of Contents

    Contents Introduction ........................2 1. Specification of Pos scale register ............... 3 2. Standard configuration of Pos scale register ............. 4 3. Pos scale installation steps ................... 4 4. Overall Appearance ....................5 4.1 Front view ...................... 5 4.2 Bottom interface view ...................5 5.
  • Page 3: Introduction

    Introduction Thank you for choosing our Pos Scale. In order to operate Pos Scale correctly, User manual is detailed in function and operation method of Pos Scale, which help user with doubt quickly when come up against mechanical fault . Rongta research, develop, produce and sale the Pos Scale independently, which is high-performance Pos Scale.
  • Page 4: Specification Of Pos Scale Register

    1. Specification of Pos scale register The Weighing range and accuracy:  Max weight: 1 Max weight: 30 Min weight: 4 Min weight: 10 0kg to 6kg * 0.002kg (e=2g) 0kg to 15kg * 0.005kg (e=5g) 6kg to 15kg * 0.005kg (e= 5g) 15kg to 30kg * 0.01kg (e= 10g) The accuracy grade: ...
  • Page 5: Standard Configuration Of Pos Scale Register

    2. Standard configuration of Pos scale register Scale pan Main body Power cable Quick installation guide 3. Pos scale installation steps Take out the scale pan and install it according to the following instructions. Align the fixing feet of the pan with the limit holes of the main body group and put them into.
  • Page 6: Overall Appearance

    4. Overall Appearance 4.1 Front view 4.2 Bottom interface view...
  • Page 7: Common Easy-To -Use Operations

    5. Common easy-to -use operations 5.1 Switch on and off Hard disk switch: After connecting power supply,long press the black POWER button on the bottom of Pos Scale register for 2 seconds until the display is turned on. After entering the normal operation screen, the program will automatically run and perform self-test counting to verify whether the CRC is correct.
  • Page 8: Troubleshooting Of Pos Scale Register

    6. Troubleshooting of Pos scale register 6.1 Crash or fail to start Reasons:a. Power line and interface error; b.Adapter error; c. Main board error. Solutions:a. Re-plug the power line; b. After power on,if the adapter indicator is off,it means the adapter is abnormal; c.The board is abnormal.
  • Page 9: Appendix Comparison Table Of Gravitational Acceleration Corrected Value

    7. Appendix Comparison Table of Gravitational Acceleration Corrected Value COUNTRY CITY G(m/sec COUNTRY CITY G(m/sec Greece Athens 9.800 Scotland Glasgow 9.816 South Cape town 9.796 Spain Madrid 9.800 Netherland Amsterdam 9.813 Singapore Singapore 9.781 Norway Oslo 9.815 Argentina Buenos Aires 9.797 Auckland,NZ 9.799...