INSTALLING YOUR FURNACE
FIGURE 1
FAN BLADE
TOP FRONT PANEL
THUMB SCREW
HANDLE
BOTTOM FRONT PANEL
The following steps are needed for proper installation and
safe operation of your furnace. If you have any doubts as
to any requirements, always consult your local Heating or
Plumbing lnspector, Building Department or Gas Utility
Company regarding regulations, codes, or ordinances
which apply to the installation of a vented wall furnace.
Obtain professional help where needed.
The CHECK AND ADJUSTMENTS on page 24 are vital
to the proper and safe operation of the furnace. Be sure
they are done.
IMPORTANT
For satisfactory and trouble-free operation, be sure to:
1. Locate the furnace properly within the space to
be heated.
2. Install the furnace in accordance with local codes or
ordinances and instructions provided. In the absence of
local codes or ordinances, install the furnace to conform
with the current edition of the National Fuel Gas Code,
NFPA 54, ANSI Z223.1/Canadian Installation Code,
CAN/CGA B149.
3. Maintain minimum clearance: Floor 0 inches or ceiling
4 inches, side wall 4 inches. For exception to minimum
side wall clearance, as shown on Page 8, Figure 3.
4. Provide enough combustion and ventilation air.
Locating Wall Furnace &
Thermostat
Consider the following points before attempting to install
the furnace:
CAUTION: Do not make cut-outs in the wall or ceiling
FAN SHIELD
before checking in the attic for ceiling joist locations
SCREWS
and proposed venting.
The counterflow vented wall furnaces are shipped ready
to install on the surface of the wall or recessed up to 9 1/4
inches into the wall, with studs 16 inches center-to-center
or stud space can be framed to 16 inches, see page 11,
Recessed Mounting.
Place the furnace near the center of the space to be
heated for good air circulation. Do not put it behind a door
or draperies.
Do not instatl the furnace in a closet, alcove, of small hallway
where the furnace could be isolated by closing doors to the
heater space.
Do not install the furnace in a mobile home, trailer, or
recreational vehicle.
The bottom of the furnace may rest directly on a wood or
concrete floor, If floor is other than wood or concrete there
must be a piece of wood or sheet metal under the furnace
CABINET
that is at teast the same size as the bottom of the furnace.
On recessed installations the recessed portion rnay have 0
inches clearance to combustible material.
To provide adequate clearance and service access the
front of the furnace must face the open room. Be sure
that gas piping and electrical wiring can be brought to the
location. See sections covering piping and electrical wiring
for your type of furnace mounting.
Furnace vent must be installed directly to the outdoors so
that combustion gases will not collect inside the building.
Provide an adequate vent or flue in accordance with local
codes or ordinances and instructions provided by the vent
pipe manufacturer.
Check the minimum spacing needs as shown on Page 8,
Figure 2 and Page 8, Figure 3.
The top of the furnace must be at least 4 inches from the
ceiling. See Figure 2.
With standard furnace discharge outlet, do not install
closer than 4 inches to intersecting wall. See figure as
shown on Page 8, Figure 3B.
When using optional kits 6703 or 6704 maintain
clearances as shown on Page 8, Figure 3A or 3C.
When using optional kit 6704 maintain clearance as shown in
Figures 3A and 3F, page 8. Use only optional outlet and grille
kits available from manufacturer.
MAGNUM FORSAIRE COUNTERFLOW TOP VENT GAS WALL HEATER
7