Ducting Guidelines

DANGER
Asphyxiation. Running engines produce carbon
monoxide, a colorless, odorless, poisonous
gas. Carbon monoxide, if not avoided, will
result in death or serious injury.
WARNING
Burn hazard. Do not remove ducting until all air
pressure has been emptied from hose duct.
Failure to do so could result in severe injury.
Place ducting in desired configuration before oper-
ating the unit.
Tightly secure ducting end to the unit. Verify any
additional ducting is also tightly secured.
Avoid sharp bends or 90° turns in the ducting.
Use only the necessary length of ducting required.
Verify that ducting is not in a high traffic area, and
will not impede workers or other machinery. Care
should be taken to prohibit the need to step or
climb over ducting.
DO NOT place ducting over combustible materials.
DO NOT place ducting over surfaces that may
cause damage or reduce performance, such as
water, sharp rocks or glass, electrical wiring, pip-
ing, etc.
DO NOT place or drape anything over ducting,
such as covers, insulation (insulated ducting is
available), blankets or cloth, or electrical wires.
Inspect ducting for damage or unusual wear before
each use.

Engine and Heater Startup

WARNING
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces could
result in severe burns or fire.
WARNING
Crushing hazard. Verify unit is properly secured and
on level ground. An unsecured unit can suddenly roll
or move, causing death or serious injury.
16
4-1, or if it is contaminated or
(000103)
(000288)
(000108)
(000234a)
WARNING
Equipment damage. Do not attempt to start or operate
a unit in need of repair or scheduled maintenance.
Doing so could result in serious injury, death, or
equipment failure or damage.
CAUTION
Equipment or property damage. Do not block air
intake or restrict proper air flow. Doing so could
result in unsafe operation or damage to unit.
CAUTION
Equipment damage. Do not cover unit during operation.
All ducting ports must remain open even if not being
used. Failure to do so will result in equipment damage.
1. Turn ignition key to RUN and wait for the light to
expire.
2. Turn ignition key to START.
NOTE: Do not hold the engine starter key in the start
position for more than 15 seconds. Doing so will overheat
the starter motor. Wait 30 seconds for the starter motor to
cool before making a second attempt to start if the engine
fails to start.
3. Warm up engine for 90 seconds.
4. See
3-1. Turn main disconnect switch to
Figure
ON.
ON
I
O
OFF
Figure 3-1. Main Disconnect Switch
5. Press green START fan button.
6. Turn burner to ON.
7. See
Ducting
Guidelines. Place heating ducts as
appropriate for the application.
IMPORTANT NOTE: A twisted or bent air duct will
cause loss of air pressure and temperature.
Owner's Manual for Indirect Fired Heater
(000291)
(000229)
(000290)