Electrical Connections: General Instructions - Xylem wtw MIQ/R6 Operating Manual

Iq sensor net
Table of Contents

Advertisement

MIQ/R6
3.5
Cable glands
All electric cables are fed from below via prepared openings in the enclosure of
the MIQ/R6. Cable glands with different clamping ranges are included with the
MIQ/R6 to provide sealing between the cable and enclosure as well as for strain
relief. Select the matching cable gland for the respective cable diameter:
 Small, clamping range 4.5 to 10 mm. This cable gland is suitable for all
 Large, clamping range 7 to 13 mm. This cable gland is required for cable
General
Observe the following points when attaching connecting wires to the terminal
installation
strip
instructions
 Shorten all wires to be used to the length required for the installation
 Always fit all the ends of the wires with wire end sleeves before connecting
ba75541d07
03/2018
All manuals and user guides at all-guides.com

Electrical connections: General instructions

IQ S
N
sensor cables.
ENSOR
ET
sealing ring 20 x 15 x 1 mm
cable gland M16
blind plug
sheaths with an outside diameter of more than 10 mm and is screwed into the
enclosure via an extension piece.
sealing ring 20 x 15 x 1 mm
extension piece M16/M20
sealing ring 24 x 19 x 2 mm
cable gland M20
If necessary, you can order more large cable glands in a set of 4
pieces (Model EW/1, Order No. 480 051).
Installation