Technical Reference; Dimensions; Environmental Requirements; Electrical Data - Xylem FLYGT MiniCAS II Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

7 Technical Reference

7.1 Dimensions

Parameter
(W×H×D)

7.2 Environmental requirements

Parameter
Temperature
Operating humidity

7.3 Electrical data

Version
Supply voltage
Supply voltage tolerance
Frequency
Relay resistive contact rating
Relay inductive contact rating
Sensor output voltage
Required power supply

7.4 Terminals

9
10
MiniCAS II Installation, Operation, and Maintenance Manual
8
7
5
3
4
11
6
1
2
Value mm (in)
33×79×75 (1.29×3.11×2.95)
Value
-25˚ C – +60˚ C
Relative humidity, non-condensing: 90%
24 VDC
24 VAC
24
24
-2%–25%
-17%–25%,
-
24 VDC, 250 VAC, 5 A
24 VDC, 250 VAC, 2 A
1. Temperature relay input
2. Power supply +
3. Temperature relay normal output
4. Temperature relay alarm output
5. Sensor input T1
6. Reset input
7. Sensor input T2
8. Leakage relay alarm output
9. Leakage relay normal output
10.Power supply -
11.Leakage relay input
7 Technical Reference
120 VAC
230 VAC
120
230
±15%
50–60 Hz
12 VDC, ±5%
5 W
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents