Oneida Air Systems Dust Deputy Low-Pro Manual

Lid separator

Advertisement

Quick Links

Patents:
www.oneida-air.com/patents
Rev: A 20230501LL
Dust Deputy Low-Pro
Appearance may vary slightly
Lid Separator
DIY / Deluxe
# AXD250099
# AXD259922
Doc. # ZBM000047

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems Dust Deputy Low-Pro

  • Page 1 Dust Deputy Low-Pro ™ Lid Separator DIY / Deluxe # AXD250099 # AXD259922 Patents: www.oneida-air.com/patents Appearance may vary slightly Rev: A 20230501LL Doc. # ZBM000047...
  • Page 2 Oneida Air Systems...
  • Page 3: System Start-Up Information

    System Start-Up Information Read the Safety PRacticeS, inStallation Ÿ and maintenance inStRuctionS, and youR wet/dRy vacuum’S owneR’S manual befoRe aSSembling and uSing the duSt dePuty. 1. DO NOT use to pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
  • Page 4: System Dimensions

    System Dimensions Nominal dimensions shown. Dimensions subject to slight varia- tions in manufacturing. 12-3/8" 315 mm 5-1/16" 129 mm 3-13/16" 98 mm 18-1/2" 470 mm As installed on a 5 Gallons 19 Liters Bucket Oneida Air Systems...
  • Page 5 System Dimensions Nominal dimensions shown. Dimensions subject to slight varia- tions in manufacturing. Tapered Inlet and Outlet 2-5/16" 59 mm 3-13/16" 98 mm 18-1/2" 470 mm As installed on a 5 Gallons 19 Liters Bucket 13-1/2" 343 mm oneida-air.com...
  • Page 6: System Contents

    Double Sided Tape RHC158716 Casters (4 Pack) RHS000004 Tether Pack AFS080375 #8 x 3/8 Sheet Metal Screw AFB148000 D ring with clip AFC000007 PSA Retainer Clip AFB100000 Split ring AFH343800 Lanyard AXD200036A 2" x 36" Hose AXD600103A 2" Elbow Oneida Air Systems...
  • Page 7 System Contents oneida-air.com...
  • Page 8 • Wet/Dry Vacuum • Bucket • Vacuum hose and adapters • Scissors / Razor Blade (2.5" recommended) Secure each Pem Stud (D2) to the Lid Separator (A) through the holes as shown in [FIG. 1]. FIG. 1 Oneida Air Systems...
  • Page 9 Assembly Instructions Apply the 5/8" Gasket (B) onto the Lid Separator (A) along the underside rim. [FIG. 2] Apply the 1/4" Gasket (C) perpindicular to the 5/8" Gasket along the lip of the Lid Separator. The 1/4" Gasket will follow the inner diameter of the 5/8" Gasket. [FIG. 2] Note: The Gasket should overlap around the circumference, firmly pressing against itself to avoid air leaks.
  • Page 10 (D2) on the Lid Separator (A) using one Wire Spring Clip (D3), one Washer (D4), and one Wing Nut (D5) as shown in [FIG. 3]. Note: Refer to Optional Grounding Instructions prior to instaling the Latch Hardware Pack (D) if necessary. FIG. 3 Oneida Air Systems...
  • Page 11 Assembly Instructions (Continued) If you did not purchase the Deluxe Unit, proceed to Step 9. Insert the Casters (I) into the Caster Mounts (G). Apply pressure and twisting motion until Wheels snap into place [FIG. 4]. FIG. 4 Ensure that the surfaces on the Bucket (F) and Caster Mounts (G) are clean and dry.
  • Page 12 Flip the Bucket (F) upside down and arrange the Caster assemblies evenly around the bottom edge [FIG. 6]. Note: We recommend arranging the Caster Assemblies at 90° increments from each other for the most stable setup. 90° FIG. 6 Oneida Air Systems...
  • Page 13 Assembly Instructions (Continued) The Caster assemblies must be adhered to the Bucket (F) with a single smooth motion so that the bottom edge of the Bucket fits within the recessed channel of the Caster Mount [FIG. 7a]. Remove the backing paper from the Double Sided Tape (H) on the Caster assembly.
  • Page 14 Attach the D ring (J2) to the vacuum with the Sheet Metal Screw. (J1) Then loop the Lanyard (J5) around the slot on the Caster Mount and through itself. Finally, clip the Lanyard to the D ring [FIG 8b] [FIG 8c]. FIG. 8a Oneida Air Systems...
  • Page 15 Assembly Instructions (Continued) FIG. 8b FIG. 8c oneida-air.com...
  • Page 16 Connect the Low-Pro's side inlet port to your tool with your vacuum's hose [FIG. 10a] [FIG. 10b]. Note: Both ports accept standard 2.5" hose cuffs (OD ≈ 2.25"). To Tool To vacuum To Tool To vacuum FIG. 10a FIG. 10b Oneida Air Systems...
  • Page 17 Assembly Instructions (Continued) Make sure there are no air leaks at the connections. Review [FIG. 11] for common leak points. Note: Any air leak will affect separation performance. Make sure to check your dust drum frequently so you do not overfill it.
  • Page 18 Install the Metal Tape (K) to the Lid Separator (A) so that the inlet, outlet, and flange are attached by a continuous, conductive path. The tape should wrap 1/4" around the edge of each opening [FIG 12]. FIG. 12 Oneida Air Systems...
  • Page 19 Optional Grounding Instructions (Continued) For added grounding, attach a self-supplied wire with a ring terminal on one end and a washer tied to the other end when installing one of the latches in step 3. The wire must be long enough for the washer to lie on the floor [FIG 13]. Wire Washer FIG.
  • Page 20: Troubleshooting

    They are available at local hardware stores in the plumbing section. not tight 2. Use a hose clamp. 3. Wrap the inlet and outlet of the Low-Pro with a layer of electrical tape to increase the friction fit. 4. Secure hose with a sheet metal screw. Oneida Air Systems...
  • Page 21 Accessories 2.5" x 4.5' wire Reinforced vacuum hose #AXD250054 • Crush-resistant, flexible hose with a smooth- wall inner lining that minimizes air resistance. 1.25" x 1.5" hose adapter kit #AKD000000 • Includes reducers, adapters, and O-rings for connecting smaller vacuum hoses to standard Dust Deputy ports.
  • Page 22 1.5" x 6.5' dust extraction hose whip #AHE000001 • This highly flexible vacuum hose fits onto the dust collection ports of common portable power tools. Includes 2.5" rotating swivel cuff. Oneida Air Systems...
  • Page 23: Warranty Information

    – activate online at oneida-air.com/warranty Oneida Air Systems, Inc. (Oneida Air Systems) warrants the Dust Deputy for a period of 1 year, to the original purchaser from the date of purchase, unless otherwise specified. Items not manufactured by Oneida Air Systems are limited to their own manufacturer’s warranties.
  • Page 24: Customer Service Department

    Thank you for your purchase of this American made product! Regardless of where you purchased your Oneida Air Systems' product, if you have any questions or issues with missing / damaged parts, please call us first to let us help resolve your problem.

This manual is also suitable for:

Axd250099Axd259922

Table of Contents