Adjustable Parameters; Order List - Dräger Interlock 7500 Instructions For Use Manual

Table of Contents

Advertisement

|

Adjustable parameters

Wait time to be ready for measurement
20 °C
2 s
0 °C
<5 s
-25 °C
<60 s
-40 °C
<110 s
10
Adjustable parameters
Some instrument parameters may be set differently by a Dräger Interlock
service centre due to legal regulations in different countries or individually
during installation. The descriptions of these Instructions for Use are related to
the basic version.
Table of essential adjustable parameters:
Parameter
Operation
Display of test result
Breath test volume
Limit value (initial test)
Restart period
Data storage
Data storage
Service
Calibration interval
Possible to start engine after the end
of the service interval
Retest
Retests (whilst the vehicle is in use)
Lockouts
30
Basic version
Test passed/Test failed
1.0 L
0.30‰ or 0.20‰
30 minutes
on
365 days
Yes
No
Parameter
Duration of the instrument lockout
after a breath alcohol test with a high
concentration
Access code
Access code (for overriding the instru-
ment for a limited time period)
11

Order list

Name and description
Mouthpieces (5 pcs), individually packaged
Mouthpieces (50 pcs), individually packaged
Mouthpieces (300 pcs), individually packaged
LTE module
Cable set for connecting headlights
Cable set for connecting horn
Cable set for connecting external equipment
(AUX/OUT)
Holster for handset
Holster V for handset
Spiral cord, length 1.5 m
Spiral cord, length 5.5 m
Instructions for use
Basic version
5 minutes
Yes
Order no.
83 26 550
83 27 627
83 22 597
83 27 080
37 01 238
37 01 237
37 01 239
83 22 497
37 24 354
83 15 909
83 20 248
®
|
Dräger Interlock
7500

Advertisement

Table of Contents
loading

Table of Contents