STIEBEL ELTRON WPE-I 05 H 400 Plus Manual

STIEBEL ELTRON WPE-I 05 H 400 Plus Manual

Ground source heat pump

Advertisement

Quick Links

WPE-I 05 H 400 Plus /
WPE-I 07 H 400 Plus /
WPE-I 10 H 400 Plus /
WPE-I 13 H 400 Plus /
WPE-I 17 H 400 Plus /
WPE-I 05 HW 400 Plus /
WPE-I 07 HW 400 Plus /
WPE-I 10 HW 400 Plus
Ground source heat pump
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WPE-I 05 H 400 Plus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STIEBEL ELTRON WPE-I 05 H 400 Plus

  • Page 1 WPE-I 05 H 400 Plus / WPE-I 07 H 400 Plus / WPE-I 10 H 400 Plus / WPE-I 13 H 400 Plus / WPE-I 17 H 400 Plus / WPE-I 05 HW 400 Plus / WPE-I 07 HW 400 Plus / WPE-I 10 HW 400 Plus...
  • Page 2: Table Of Contents

    Table of contents 1 Special information ........... 3 14 Specification............. 13 14.1 Dimensions and connections......13 2 General information..........3 14.2 Output diagrams..........15 Symbols in this document ........ 3 14.3 Wiring diagram ..........22 Units of measurement ........3 14.4 Data table............
  • Page 3: Special Information

    Special information Special information Symbol Meaning This symbol indicates that you must fulfil certain pre-  requisites before you perform the following steps. – The following groups of people are not per- This symbol indicates a result or intermediate result. ...
  • Page 4: Safety

    Safety Qualified heating contractor Symbol Type of risk Electrocution Person with specialist expert knowledge in the following areas: heating technology, heating media, building services and engin- eering, ventilation and air conditioning technology, measuring Burns, scalding technology, heat pump technology, environmental technology, occupational safety and fire safety Qualified electrical contractor 3.1.4 Signal words...
  • Page 5: Appliance Description

    DHW cylinder (not part of the standard delivery). Output Heat exchanger surface area Function WPE-I 05 H 400 Plus 2 m² – A sealed refrigerant circuit routes the refrigerant from the WPE-I 05 HW 400 Plus appliance into the ground and back again. The refrigerant...
  • Page 6: Installation (Qualified Contractors)

    Installation (qualified contractors) – Ensure that the entire appliance frame is in full contact with the substrate. Uneven substrates can increase sound emis- sions. – Avoid installation on large, echoing floor areas, e.g. tiled floors. – Implement pipe outlets through walls and ceilings with anti-vibration insulation.
  • Page 7: Creating Wall Outlets

    Installation (qualified contractors) WPE-I HW 400 Plus ≥300 ≥300 ≥50 ≥600 D0000109647 Installing and filling the brine circuit Routing the brine lines through the wall outlets D0000109541 – Route the brine lines through separate wall outlets. Creating wall outlets – Route the brine lines through the wall outlets. u Establish wall outlets in the building wall with a slight fall –...
  • Page 8: Installing The Heating Circuit

    Installation (qualified contractors) Charging the brine circuit u NOTICE: Foreign bodies, such as rust or sealing material, 1,10 can impair the operational reliability of the heat pump. Be- fore connecting the heat pump to the heat source circuit, 1,09 flush the pipework thoroughly with brine. 1,08 u Connect the appliance to the brine circuit.
  • Page 9: Connecting The Wpe-I H To The Dhw Cylinder

    Installation (qualified contractors) Heating circuit oxygen diffusion u Vent the heating coil of the DHW cylinder via the air vent valve on the DHW cylinder e07 (WPE-I HW 400 Plus) or via If oxygen gets into the heating system, steel parts may become the air vent valve on the external DHW cylinder (WPE-I H corroded, e.g.
  • Page 10: Temperature Sensor

    Installation (qualified contractors) Model Com- Compressor with electric emergency/ pressor auxiliary heater Com- Com- Compressor pressor + pressor + + 9 kW 3 kW 6 kW (stage 3) (stage 1) (stage 2) L1 L2 L3 N PE PE 2L 2N PE WPE-I 07 H 6 A 13 A 16 A 20 A 400 Plus...
  • Page 11: 6.10 High Limit Safety Cut-Out

    Commissioning (qualified contractors) u Replace the cover. Commissioning (qualified contract- ð The cover clicks audibly into place. ors) Contact sensor AVF 6 Our customer support can assist with commissioning, which is a Install the sensor in the heating circuit flow if you wish to use a chargeable service.
  • Page 12: Cleaning (Users)

    Notify a qualified con- tractor if the fuses/ Brine circuit MCBs blow/trip again after switching the Ask STIEBEL ELTRON customer service for recommendations for system back on. the brine circuit filter. u If you cannot remedy the fault, contact a qualified con- tractor.
  • Page 13: Specification

    Shutdown (qualified contractors) 14 Specification 14.1 Dimensions and connections D0000109652 u Remove the cause of the fault. u Reset the high limit safety cut-out by pressing the reset but- ton. D0000109629 WPE-I H 400 Plus D0000110518 u Check whether the heating water is being circulated at a sufficiently high flow rate.
  • Page 14 Specification WPE-I HW 400 Plus D0000109665 WPE-I 05 WPE-I 07 WPE-I 10 WPE-I 13 WPE-I 17 WPE-I 05 WPE-I 07 WPE-I 10 H 400 H 400 H 400 H 400 H 400 HW 400 HW 400 HW 400 Plus Plus Plus Plus Plus...
  • Page 15: Output Diagrams

    Specification 14.2 Output diagrams 14.2.1 WPE-I 05 H(W) 400 Plus Heating output WPE-I_05_Plus_Waermeleistung Flow temperature of the heat pump [°C] Temperature of heat source system [°C] 35 °C 55 °C Heat pump heating output 45 °C 60 °C Power consumption WPE-I_05_Plus_Leistungsaufnahme Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Electrical power consumption of the heat pump with auxiliary drives...
  • Page 16 Specification Coefficient of performance WPE-I_05_Plus_Leistungszahl Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Coefficient of performance 14.2.2 WPE-I 07 H(W) 400 Plus Heating output WPE-I_07_Plus_Waermeleistung Flow temperature of the heat pump [°C] Temperature of heat source system [°C] 35 °C 55 °C Heat pump heating output...
  • Page 17 Specification Power consumption WPE-I_07_Plus_Leistungsaufnahme Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Electrical power consumption of the heat pump with auxiliary drives Coefficient of performance WPE-I_07_Plus_Leistungszahl Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Coefficient of performance www.stiebel-eltron.com WPE-I H(W) 400 Plus |...
  • Page 18 Specification 14.2.3 WPE-I 10 H(W) 400 Plus Heating output WPE-I_10_Plus_Waermeleistung Flow temperature of the heat pump [°C] Temperature of heat source system [°C] 35 °C 55 °C Heat pump heating output 45 °C 60 °C Power consumption WPE-I_10_Plus_Leistungsaufnahme Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Electrical power consumption of the heat pump with auxiliary drives...
  • Page 19 Specification Coefficient of performance WPE-I_10_Plus_Leistungszahl Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Coefficient of performance 14.2.4 WPE-I 13 H 400 Plus Heating output WPE-I_13_Plus_Waermeleistung Flow temperature of the heat pump [°C] Temperature of heat source system [°C] 35 °C 55 °C Heat pump heating output...
  • Page 20 Specification Power consumption WPE-I_13_Plus_Leistungsaufnahme Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Electrical power consumption of the heat pump with auxiliary drives Coefficient of performance WPE-I_13_Plus_Leistungszahl Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Coefficient of performance | WPE-I H(W) 400 Plus www.stiebel-eltron.com...
  • Page 21 Specification 14.2.5 WPE-I 17 H 400 Plus Heating output WPE-I_17_Plus_Waermeleistung Flow temperature of the heat pump [°C] Temperature of heat source system [°C] 35 °C 55 °C Heat pump heating output 45 °C 60 °C Power consumption WPE-I_17_Plus_Leistungsaufnahme Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Electrical power consumption of the heat pump with auxiliary drives...
  • Page 22: Wiring Diagram

    Specification Coefficient of performance WPE-I_17_Plus_Leistungszahl Flow temperature of the heat pump [°C] Temperature of heat source system [°C] Coefficient of performance 14.3 Wiring diagram BM card Description 605.T36 Y605 T36 DHW top sensor BM card Description 605.T37 DHW bottom sensor Y501 X11 Heating element 606.13...
  • Page 23: Data Table

    Specification 14.4 Data table WPE-I 05 WPE-I 07 WPE-I 10 WPE-I 13 H WPE-I 17 H WPE-I 05 WPE-I 07 WPE-I 10 H 400 H 400 H 400 400 Plus 400 Plus HW 400 HW 400 HW 400 Plus Plus Plus Plus Plus...
  • Page 24: Guarantee

    Guarantee WPE-I 05 WPE-I 07 WPE-I 10 WPE-I 13 H WPE-I 17 H WPE-I 05 WPE-I 07 WPE-I 10 H 400 H 400 H 400 400 Plus 400 Plus HW 400 HW 400 HW 400 Plus Plus Plus Plus Plus Plus Condenser material 1.4401/Cu...
  • Page 25 www.stiebel-eltron.com WPE-I H(W) 400 Plus |...
  • Page 26 | WPE-I H(W) 400 Plus www.stiebel-eltron.com...
  • Page 27 www.stiebel-eltron.com WPE-I H(W) 400 Plus |...
  • Page 28 Comfort through Technology STIEBEL ELTRON International GmbH Dr.-Stiebel-Straße 33 / 37603 Holzminden / Germany info@stiebel-eltron.com / www.stiebel-eltron.com 4 0 1 7 2 1 3 5 8 3 7 9 0...

Table of Contents