GR SERIES GAS FRYERS - TROUBLESHOOTING
SOLID STATE OR COMPUTER CONTROL HARNESS PIN-OUTS
PIN NO.
E1-1
E1-2
E1-3
E1-4
E1-5
Drain Valve Interlock (24VAC) N.O.
E1-6
Ignition Status (24VAC)
E1-7
Relay DC (-) Common
NOTES:
1. Connected to ground internally.
Interface Control Board.
PIN NO.
P1
24VDC Left Basket Lift
P2
24VDC Right Basket Lift
P3
24VDC Heat Demand Control
P4
P5
Heat Demand Triac (24VAC)
P10
Relay Contacts (24VAC)
NOTES:
1. Relays connected internally.
FRYMATE (DUMP STATION) WITH OPTIONAL HEATER
SYMPTOM
No heat.
INPUTS
24VAC Hot
24VAC Neutral
1
Probe High (red)
Probe Low (white)
2. Available for external buzzer output (24VDC).
INTERFACE CONTROL BOARD PIN-OUTS
INPUTS
Control Common (-)
1
2. To "TH" Terminal on gas valve (main). 3. To basket lift relay coils.
PIN NO.
E1-8
E1-9
E1-10
E1-11
E1-12
—
—
PIN NO.
P6
P7
P8
P9
—
—
POSSIBLE CAUSES
1.
Unplugged.
2.
Power switch off or inoperative.
3.
Main circuit breaker off or open.
4.
Malfunctioning heat assembly.
– 45 –
OUTPUTS
3
24VDC (+) Heat Demand
Not used at this time
2
24VDC (+) Left Basket Lift
24VDC (+) Right Basket Lift
No connection
—
—
3. Outputs to
OUTPUTS
3
Heat Demand Triac (24VAC)
System Ground
24VAC Left Basket Lift
24VAC Right Basket Lift
—
—
F-25114 Rev.A (07-03)
2
3
3