High Limit Thermostat - Vulcan-Hart GRC35 Service Manual

Gr series gas fryers with tridelta controls
Table of Contents

Advertisement

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS
6. Remove screws securing probe mounting clips and
probe to the fryer heat tube (inside tank) then remove
probe.
7. Reverse procedure to install.
8. Check cooking controls calibration as outlined in
"COOKING CONTROL CALIBRATION" under
"SERVICE PROCEDURES AND ADJUSTMENTS".

HIGH LIMIT THERMOSTAT

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES. THERE MAY
BE MULTIPLE CIRCUITS. BE SURE
ALL CIRCUITS ARE DISCONNECTED.
WARNING: SHUT OFF THE GAS
BEFORE SERVICING THE UNIT.
CAUTION: Do not sharply bend and kink the
temperature probe or damage may occur.
1. Drain frying oil from fryer tank.
2. Remove burners as outlined under "GAS BURNERS".
3. Disconnect lead wires from high limit thermostat.
4. Remove screws securing the high limit to mounting
bracket.
5. Remove the capillary tube retaining and packing
nuts, from the bottom of fry tank.
6. Remove screws securing mounting clips and capillary
tube to the fryer heat tube (inside tank) then remove
capillary tube.
– 13 –
F-25114 Rev.A (07-03)

Hide quick links:

Advertisement

Table of Contents
loading