GR SERIES GAS FRYERS - ELECTRICAL OPERATION
Filter Power Switch .................................... Supplies 120VAC to pump motor. Filter valve switch or discard valve
Pump Motor ................................................. Operates pump to circulate frying oil through filtering system.
Filter Valve Switch ...................................... Energizes pump motor to filter the frying oil when switch is closed (valve
Discard Valve Switch ................................. Energizes pump motor to discard the frying oil from filter tank when switch
F-25114 Rev.A (07-03)
KLEENSCREEN FILTER CONTROLS
switch must be closed (valve handle extended).
handle extended). Filter power switch must be turned on. When oil filtering
is complete, close the manual drain valve to the fryer and allow the fry tank
to refill. Return the switch to the N.O. position (valve handle retracted)
when all filtered oil is returned to fry tank.
is closed (valve handle extended). Filter power switch must be turned on.
Oil is discarded through the discard hose into a separate container. When
filter tank is empty, return the switch to the N.O. position (valve handle
retracted) when all frying oil is discarded.