Setting Up The Instruction Set - Ebyte E52-400/900NW22S User Manual

400/900mhz 160mw ttl lora mesh wireless networking module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd..
AT+HEAD=?
AT+SECURITY=?
AT+RESET_AUX=?
AT+RESET_TIME=?
AT+FILTER_TIME=?
AT+ACK_TIME=?
AT+ROUTER_TIME=?
AT+GROUP_ADD=?
AT+GROUP_DEL=?
AT+GROUP_CLR=?
AT+ROUTER_CLR=?
AT+ROUTER_SAVE=?
AT+ROUTER_READ=?
AT+MAC=?
AT+KEY=?

6.4 Setting up the instruction set

Set the command suffix to "=%d,%d,%d", for example, set the module target address command
"AT+DST_ADDR=25640,0", the first parameter is the target address, and the second parameter is whether to save
to Flash , the middle needs to be separated by ",".
If there is no <save> parameter in the setting command, it will be saved in Flash.
Query whether the extra
frame header function is
enabled
Query whether the data
encryption function is
enabled
Query whether LED2
changes during automatic
reset
Query the automatic reset
time
Query broadcast filter
timeout
Query request response
timeout
Query routing request
timeout
Query GROUP
information
Query routing table
information
Query MAC unique
address
Query encryption key
12
Returns whether the extra frame header function is
Returns whether the data encryption function is
Returns whether LED2 changes to turn on when the
radio frequency is restarted.
Returns the radio frequency automatic restart time,
Returns the broadcast filter timeout
Return request response timeout
Returns the routing request timeout
Return multicast group address table
Return routing table information
Returns the MCU's unique 32-bit MAC address
Unable to read to avoid key leakage
CopyriCopyright ©2012–2023, Chengdu Ebyte Electronic Technology Co.,Ltd.
E52-400/900NW22S User Manual
enabled
enabled
unit min

Advertisement

Table of Contents
loading