Introduction To Remote Broadcast Configuration - Ebyte E52-400/900NW22S User Manual

400/900mhz 160mw ttl lora mesh wireless networking module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd..
(Unicast);
Step 3: Module A uses the "AT+DST_PORT=14,0" command to modify the target port to the remote parsing AT
command function;
Step 4: Module A sends the AT command "++AT+PANID=4660,0". If sent successfully, SUCCESS will be returned;
Step 5: After receiving the instruction, module B will output the execution result of the corresponding instruction
through the serial port after waiting for a route establishment timeout, and respond with "+OK:" or "+FAIL:" through the
radio frequency, and will send the current module The parameters are sent via radio frequency, and
returned if the transmission is successful;
Step 6: Module A receives the module information responded from module B and outputs it through the serial port.

8.3 Introduction to remote broadcast configuration

The basic steps for remote broadcast configuration are as follows:
Step 1: Module A uses the "AT+OPTION=3,0" command to change the communication mode to broadcast mode
(Broadcast);
Step 2: Module A uses the "AT+DST_PORT=14,0" command to modify the target port to the remote parsing AT
command function;
Step 3: Module A sends the AT command "++AT+PANID=4660,0". If sent successfully, SUCCESS will be returned;
Step 4: After receiving the instruction, module B waits for a route establishment timeout period and then outputs the
execution result of the corresponding instruction through the serial port.
Figure 8.2.1 Remote single point configuration steps
26
CopyriCopyright ©2012–2023, Chengdu Ebyte Electronic Technology Co.,Ltd.
E52-400/900NW22S User Manual
SUCCESS
will be

Advertisement

Table of Contents
loading

Table of Contents