7.1 Default Parameter

Model
Frequency
E30-TTL-100
433MHz
Model
Frequency
E30-T100S2
433MHz

7.2 Reading Operating Parameters

Instruction format
C1+C1+C1

7.3 Reading Version Number

Instruction format
C3+C3+C3

7.4 Reset Instruction

Instruction format
C4+C4+C4

7.5 Parameter Setting Instruction

No.
Item
0
HEAD
Fix 0xC0 or 0xC2, it means this frame data is control command
1
ADDH
2
ADDL
7
0
0
3
SPED
1
1
5
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
Default parameter values:C0 00 00 18 50 44
Address
Channel
0x0000
0x50
Default parameter values:C0 00 00 18 50 44
Address
Channel
0x0000
0x50
In sleep mode(M0=1,M1=1) ,
User gives the module instruction (HEX format): C1 C1 C1,
Module returns the present configuration parameters.
For example, C0 00 00 1A 17 44.
In sleep mode(M0=1,M1=1),
User gives the module instruction (HEX format): C3 C3 C3,
Module returns its present version number, for example C3 30 xx yy.
30 here means the module model (E30 series); xx is the version number and yy refers to the other module
features.
In sleep mode(M0=1,M1=1),
User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time. During the reset
process, the module will conduct self-check, AUX outputs low level. After reset completing, the AUX outputs
high level, then the module starts to work regularly which the working mode can be switched or be given
another instruction.
Description
High address byte of module
(the default 00H)
Low address byte of module
(the default 00H)
6
UART parity bit
0
8N1(default )
1
8O1
0
8E1
1
8N1
4
3
TTL UART baud rate(bps)
Air data rate
Baud rate
1kbps
9600
Air data rate
Baud rate
1kbps
9600
Description
Description
Description
Must be 0xC0 or 0xC2
C0: Save the parameters when power-down
C2: Do not save the parameters when
power-down
00H-FFH
00H-FFH
UART mode can be different between
communication parties
UART baud rate can be different between
User Manual of E30 Series Modules
Transmitting power
Parity
8N1
100mW
Parity
Transmitting power
8N1
100mW
Remark