Page 2
E-mail: skope@skope.com Website: www.skope.com Trademark Infringement The SKOPE trademark on this product is infringed if the owner, for the time being, does any of the following: • Applies the trade mark to the product after its state, condition, get-up or packaging has been altered in any manner.
Asphyxiation. Do not interfere with the refrigeration system. All refrigeration maintenance and repairs must be undertaken according to the SKOPE Hydrocarbon Service Requirements below. Electrical safety precautions Correct wiring routing is as important as use of correct components for compliance with safety and radio interference regulations.
Hydrocarbon work – SKOPE Service Policy It is the responsibility of the service technician to follow SKOPE’s Hydrocarbon equipment service policy and by accepting a service work order they agree to the following (where applicable): MUST – Ensure all workers are trained in the SAFETY of hydrocarbon products to the appropriate level for the work required.
SKOPE ReFlex ChefBase Fridge 2 Specifications Models This service manual applies to the SKOPE ReFlex ChefBase Fridge models listed in the table below. Refer to the relevant product specification sheet (available on the SKOPE website: www.skope.com) for specifications. Table 1: Model specifications...
SKOPE ReFlex ChefBase Fridge 3 Installation Installation Guidelines When installing this cabinet, ensure the installation guidelines below are considered and met. Surface Climate Class Ventilation Door Opening Ensure all The installation Allow adequate The cabinet must be installed ventilation surface must be...
SKOPE ReFlex ChefBase Fridge Cleaning Before First Use The cabinet interior and food contact surfaces such as the worktop must be thoroughly cleaned and sanitised before first use. Ensure the cabinet is unplugged from the power supply before cleaning, and use only standard stainless steel cleaners suitable for food preparation areas. If required, the cabinet exterior can be cleaned as instructed in the cleaning section of this service manual (see “Maintenance”...
See “SCS Connect Field App and Track App” on page 12 for information on setting up and using the app. SCS Connect The AoFrio Track app for mobile devices transfers data from SKOPE equipment that uses the SCS Connect controller to a cloud-based server. Track App The app works automatically in the background.
Service mode categories available from the controller faceplate include: Parameters Allows you to access and edit individual controller parameters. SKOPE does not recommended changing the parameters unless absolutely necessary. If incorrect parameter settings are suspected, reload the complete parameter set. Reset Returns the controller back to factory settings.
1. Download the SCS Connect Field app from Google Play Store or Apple App Store. 2. Enter your unique Activation Code and press ‘Activate’. The activation code is provided by SKOPE Customer Services. 3. Enter a 4-digit PIN code, re-enter the code, and press ‘SET PIN CODE’.
Store or Apple App Store. 2. Enter your unique Activation Code and press ‘Activate’ (the same code as used for SCS Connect Field app). The activation code is provided by SKOPE Customer Services. 3. Respond to any dialogue boxes that appear and the app should be ready to use.
Page 14
SKOPE ReFlex ChefBase Fridge Home screen The home screen shows a graphical representation of the current state of the cabinet being controlled. Output control Provides control of the controller input sensors and switches, and output relays. Edit parameters Provides access and editing of individual controller parameters.
The service tech type column refers to the service tech skill level required to complete a task. Refer to the SKOPE HC Service Policy (available from SKOPE) for service tech type details. Table 4: Faults (alarm indicator lit, no message displayed)
Page 16
SKOPE ReFlex ChefBase Fridge Table 5: Alarms Service tech Code Description Possible root cause type Door left open. • Door not self closing (torsion fault) The door has been open for several minutes. 1, 2, 3, 4 • Door switch or circuit Will revert to door left open FAULT after 10 •...
Page 17
SKOPE ReFlex ChefBase Fridge Table 5: Alarms (continued) Service tech Code Description Possible root cause type Take a spare cartridge in case of refrigeration system fault. • Condenser blocked • Poor installation or ventilation Failed to reach set temperature • Frozen blocked evaporator coil The refrigeration system has been operating •...
Page 18
SKOPE ReFlex ChefBase Fridge Table 5: Alarms (continued) Service tech Code Description Possible root cause type Take a spare cartridge in case of refrigeration system fault. • Condenser blocked • Poor installation or ventilation Compressor cutting out • Cabinet, door or cartridge seal leaking...
SKOPE ReFlex ChefBase Fridge 5 Replacement Procedures Drawers Alignment If a drawer is out of alignment, realign it by loosening the top and/or bottom drawer bracket fixing screws, move the drawer as required, and re-tighten the bracket screws. Adjustment Drawer Gasket The one-piece drawer gasket clips into the drawer frame and runs around the perimeter of the drawer.
Ensure you have read and understood this manual before starting any servicing. Important • SKOPE hydrocarbon refrigeration systems must only be serviced by appropriately skilled and qualified refrigeration mechanics. • Servicing a sealed refrigeration system must occur at a hydrocarbon workshop or service area with dedicated hydrocarbon equipment and personal protective equipment (PPE).
Must have no ignition sources, nor any areas where the gas may pool. • Must be able to transport swap units. • Should carry minimum SKOPE hydrocarbon service parts. On-site Work The service technician must have required knowledge, skills, qualifications, and tools before beginning any on-site work on the refrigeration sealed system.
SKOPE ReFlex ChefBase Fridge Electrics Panel and Loom Electrical Connections Manufactured Due to the use of limited colour connectors, 2 × red 4-way and 2 × yellow 4-way connectors have been used. Always ensure reconnection has been undertaken correctly as operational Feb.
SKOPE ReFlex ChefBase Fridge Due to the confined space within the electrics box, plugs may come loose as a result of movement and vibrations during servicing. Take care when refitting to ensure all plugs are securely attached to the correct sockets.
Procedure 9: To access and remove the condenser fan assembly Before you start Make sure you take note of the cable’s routing. SKOPE recommends taking a photograph. 1. Disconnect the cabinet from the power supply, remove the cartridge cover and remove the left hand panel (see Procedure 7, “To replace the end panel”, on page 21).
Page 26
The fan assembly is fixed to evaporator shroud with screws and metal bars. IMPORTANT Replace the motor with the same SKOPE OEM part. DO NOT use alternative parts. It is important that you replace the assembly with the same part to ensure safety, correct alignment and refrigeration performance, and compliance.
SKOPE ReFlex ChefBase Fridge Procedure 12: To access and replace the evaporator fan assembly (continued) 4. Unscrew all the evaporator fan shroud mounting screws. 5. Remove the evaporator assembly. 6. Reassemble the cartridge and test. Compressor The compressor is located at the back of the refrigeration cartridge. If the compressor is causing excessive noise, check the mountings to ensure there is no damage to the rubber or the washers, nuts and screws.
SKOPE ReFlex ChefBase Fridge Electronic Controller The electronic controller and electrics panel is matched to the cabinet, and must be left with the cabinet when servicing the refrigeration cartridge. Only specific components can be replaced in the cartridge. Different controller parameter sets are used across different models. Ensure the controller is set up with the correct parameter set for the cabinet model.
Page 29
12. Set up controller and cabinet links as required: • Corporate: The service tech must link the controller to the cabinet serial number in the SCS Connect Field app. • General Market: The owner must set up SKOPE-connect (if in use). Replacement Procedures Service Manual...
Procedure 15: To replace the control probe Before you start Make sure you take note of the cable’s routing. SKOPE recommends taking a photograph. 1. Gain access to the evaporator fan assembly (see steps 2 to 3 in Procedure 12, “To access and replace the evaporator fan assembly”, on page 26).
Procedure 17: To replace the condenser probe Before you start Make sure you take note of the cable’s routing. SKOPE recommends taking a photograph. 1. Disconnect the cabinet from the power supply and remove the left hand end plate (see Procedure 7, “To replace the end panel”, on page 21).
Page 33
Refer to the Plug type/colour column in Table 7 below for colour variations. After unplugging connectors, ALWAYS ensure reconnection has been undertaken correctly as operational faults may occur if not. For future reference, SKOPE recommends that you photograph the wiring setup before unplugging.
Condenser Coil The condenser coil must be kept clean. SKOPE strongly recommends monthly cleaning of the condenser coil and air filter. Do not use hard or sharp tools to clean the coil as these may cause damage.
Page 38
SKOPE ReFlex ChefBase Fridge Procedure 19: To clean the condenser coil and condenser filter 1. Unplug the cabinet from the mains power supply. The filter is located behind the cartridge bottom grille. Cartridge 2. Rotate the grille out and slide the filter up and bottom grille off the cabinet.
SKOPE ReFlex ChefBase Fridge 9 Troubleshooting and Diagnostics Electronic Controller Alarms signal unexpected operational changes in the cabinet or cartridge. When an alarm is activated, use the electronic controller app to diagnose the fault, and service as necessary. See “Faults and Alarms” on page 15 for information.
1 hour) maximum operating temperature. Refrigeration System Unlike other SKOPE cabinets, the ChefBase refrigeration system is integrated into the cabinet and can not be easily removed. The condensing unit can be easily accessed by removing the side panels. The evaporator can only be removed safely by degassing the entire unit, detaching the entire benchtop, and cutting or detaching the suction line.
Need help?
Do you have a question about the ReFlex ChefBas and is the answer not in the manual?