TOOLS REQUIRED ........................... 9 4.2 PACKAGING CONTENT ........................9 4.3 TABLETOP INSTALLATION .........................10 4.4 WALL MOUNT INSTALLATION ......................10 USING THE TONOCARE....................11 CONTROLS AND INDICATORS ......................11 5.2 MENU MAP ..............................13 MEASUREMENT PROCEDURE ..................14 ROUTINE CHECKS AND FUNCTIONAL TESTS .................14 6.2 PREPARING THE DEVICE ........................15...
Page 6
TonoCare by KEELER 15. APPENDIX ...........................28 15.1 REPEATABILITY AND REPRODUCIBILITY..................28 15.2 CLINICAL PERFORMANCE DATA ....................28...
Page 7
Atmospheric pressure limitation Medical device Humidity limitation Translation The Keeler TonoCare is designed and built-in conformity with Directive 93/42/EEC, Regulation (EU) 2017/745 and ISO 13485 Medical Devices Quality Management Systems. Classification: CE / UKCA: Class IIa FDA: Class II The information contained within this manual must not be reproduced in whole or part without the manufacturer’s prior written approval.
Page 8
TonoCare by KEELER Symbols used on controls and display These symbols will be used on the device and display during operation. Device Controls Display Symbols Description On / Standby Light Turn On / Off illumination LEDs button Menu button Sound...
The Keeler TonoCare should not be used in patients with high corneal astigmatism (>3D). The Keeler TonoCare Tonometer uses the principle of air impulse tonometry – this is a variation of general applanation tonometry, however, does not require direct contact with the surface of the eye.
• Only use approved Keeler power supply EP29-32777 or instrument may malfunction. • If transporting the TonoCare in temperatures of less than 10°C, ensure the device has had at least three hours to acclimatise to room temperature before use. •...
Page 11
• Contact of the front window / nozzle area of the TonoCare with the eye of the patient should be avoided. If accidental contact occurs, clean the front window and surrounding area according to the cleaning instructions in section 3.1.
It is recommended that these factors are considered during IOP measurement. The Keeler TonoCare should not be used in patients with high corneal astigmatism (>3D). 3. CLEANING INSTRUCTIONS CAUTION: Only manual non-immersion cleaning as described should be used for this tonometer.
4. Safely dispose of used cleaning materials. 4. INSTALLATION This section will instruct how to unpack and prepare the TonoCare for use. CAUTION: When you open the package, check for any external damage or flaws, particularly damage to the case. If you suspect there is something wrong with the tonometer, contact the manufacturer or distributor.
Route power cords safely to eliminate risk of tripping to user, or damage to device. 8. The LED indicator in the Hand Unit should now light up to indicate the TonoCare battery is charging. 9. Use the USB cable provided to connect the Docking Station to a computer (not provided) for data export.
This section will instruct the user on how to interpret the controls and indicators of the TonoCare, and how to perform the IOP measurement on a patient using the device. Familiarise yourself with the instructions for the measurement of the IOP using the TonoCare, before using the instrument on a patient.
Page 16
TonoCare by KEELER Note: The LED indicator on the TonoCare pulses when charging and remains solid when fully charged Isometric view from the user and left side Forehead Rest Eyepiece View from underneath the tonometer Charging contacts Power input Patient view...
TonoCare by KEELER Underside view Power input USB interface – Allows tonometer to be connected to a PC for raw data upload purposes. View to show position of Hand Unit with Docking Station 5.2 MENU MAP Press the Menu button to open the Software Menu. Once in Software Menu, use the Menu button to change your selection, the Print button to confirm and the Return button to move to the previous menu.
1. Before daily use, visually examine the Hand Unit and Docking Station, looking for any signs of obvious damage. If you suspect the tonometer has been subjected to any impacts or moisture ingress do not use the tonometer. Contact Keeler or your local service centre for advice.
Hand Unit will enter Standby Mode if not used for more than 90 seconds. 6.3 PREPARING THE PATIENT Before using the TonoCare tonometer you should make your patient feels at ease and ensure they are in an optimum reading location, preferably with their head supported. This is because apprehension and nervousness may adversely affect the readings obtained.
Page 20
12. When two consecutive readings are within 1mmHg, an audible high pitch tone will be heard indicating that sufficient readings may have been taken (if Buzzer is enabled in the User Menu Options). If successive readings are not within 1mmHg of each other, Keeler recommends taking up to four readings and using the average.
TonoCare by KEELER 13. Press the OD / OS button to switch from left to right eye, or vice-versa. 14. Press and hold the OD / OS button to clear all the readings. 15. Pressing the Print button will produce a paper printout from the printer installed in the Docking Station.
Page 22
TonoCare by KEELER TonoCare CCT Workflow Obtain readings for either one or both eyes OD/OS Button Menu button Menu button Short press Short press CCT dialog CCT dialog (selection list) (selection list) Show CCT Return button Return button screen: OD/OS button toggles: 1.
The last four individual readings are printed as whole numbers ‘XX’. The average IOP is calculated and printed to one decimal place ‘XX.X’. Always verify that the data on the printout and data on the TonoCare Export application matches the readings on the Hand Unit.
8.1 CHARGING YOUR TONOCARE When not in use Keeler recommends storing your TonoCare on the Docking Station, so that it is maintained fully charged and ready for use. The LED on the TonoCare pulses when charging.
If the TonoCare is to remain unused for any length of time, press the On / Off Push button switch to ‘Off’ and remove the power supply. Use the dust cover to protect the tonometer.
TonoCare by KEELER 11. SPECIFICATIONS AND ELECTRICAL RATINGS The Keeler TonoCare is a medical electrical instrument. The instrument requires special care concerning electromagnetic compatibility (EMC). This Section describes its suitability in terms of electromagnetic compatibility of this instrument. When installing or using this instrument, please read carefully and observe what is described here.
Page 27
– guidance Test level Portable and mobile RF communications equipment should be used no closer to any part of the Keeler TonoCare, including cables, than the recommended separation distances calculated from the equation applicable to the frequency of the transmitter.
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Keeler TonoCare is used exceeds the applicable RF compliance level above, the Keeler TonoCare should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orientating or relocating the Keeler TonoCare .
The Mains plug is the means of isolating the device from the mains supply – ensure the Mains Plug is accessible at all times. Note 1: If connecting the TonoCare to a computer, the computer shall comply with the requirements of EN 60601-1: Note 2: Whenever the device is connected to other equipment, the combination shall comply with the requirements of EN 60601-1: The ME Equipment includes the Hand Unit, the Docking Station, the Forehead Rest and the power supply.
Page 30
TonoCare by KEELER Docking Station Docking Station dimensions 153 x 155 x 183mm (H x W x D) Docking Station weight 0.725Kg Electric shock protection Class II IP rating IPX0 Power Supply Unit Switch mode, multi-plug type (110 – 240V) +/- 10%...
TonoCare by KEELER 13. ACCESSORIES AND SPARES Item Part Number Dock 2418-P-5002 Headrest 2418-P-7000 Power supply kit EP29-32777 TonoCare carry case 3418-P-7000 Tonometer face shield 2415-P-7038 Printer paper roll 2208-L-7008 14. PACKAGING AND DISPOSAL INFORMATION Disposal of old electrical and electronic equipment This symbol on the product or on its packaging and instructions indicates that this product shall not be treated as household waste.
Page 32
Two measurements (an average of 4 readings) at the 5 pressure values were taken for each of the six test cases (each operator using each of the three TonoCare devices). An Analysis of Variance (ANOVA) conducted on the data indicates a p-value of less than 0.05 and an R-square value of 98% or 99%, which signifies excellent reproducibility across operator and across devices.
Page 33
TonoCare by KEELER Overall, the mean of IOP differences between TonoCare and Perkins AT was <0.01 mmHg, with a median of -0.2mmHg, indicating that the TonoCare NCT is equivalent to the applanation tonometer. Methods The study conducted was a single visit, single- centre, non-randomized, non-masked paired crossover study.
Page 34
** In order to obtain measurements in this range, an inversion procedure was performed on a subset of participants while taking IOP measurements. Table 2 categorises the absolute differences between TonoCare and Perkins AT IOP measurements >5mmHg overall, and within 3 IOP subgroups. A difference greater than the tolerance of ±5mmHg occurred in 1 (0.7%) eye out of 144, well below the maximum level of...
Page 35
Table 3 below, for the full sample and by each IOP group. Overall the mean of IOP differences between TonoCare and Perkins AT was <0.01 mmHg, with a median of -0.2mmHg. The 95% limits of agreement, based on the mean of IOP differences ±1.96 ×...
Page 53
KEELER社製TonoCare TonoCare CCTワークフロー Obtain 片眼または両眼 の測定値を取得 readings for します either one or both eyes OD/OS OD/OSボ タン Button メニューボタン メニューボタン Menu button Menu button 短く押す 短く押す Short press Short press CCT dialog CCT dialog CCTダイアログ CCTダイアログ (選択リスト) (選択リスト) (selection list) (selection list) 戻るボタン...
Page 61
KEELER社製TonoCare ドッキングステーション ドッキングステーション寸法 153 x 155 x 183mm (H x W x D) ドッキングステーション重量 0.725Kg 感電防止 クラス II IP等級 IPX0 スイッチモード、マルチプラグ型(110 – 240V) +/- 10% 電源供給装置 350-700mA 以下に適合�EN 60601-1, EN 61000-6-2, EN 61000-6-3 電源出力 30 VA (12V DC 2.5A) 周波数...
Page 67
6.4 THỰC HIỆN ĐO DỮ LIỆU ................... 77 6.5 CĂN CHỈNH CCT ....................79 IN ........................81 THAY THẾ GIẤY IN .................... 81 8.1 SẠC THIẾT BỊ TONOCARE CỦA BẠN ..............82 BẢO TRÌ ......................82 9.1 MÃ LỖI ......................... 83 10. BẢO HÀNH ......................83 11. THÔNG SỐ KỸ THUẬT VÀ ĐỊNH MỨC VỀ ĐIỆN..........
Page 68
Thiết bị TonoCare của KEELER 15. PHỤ LỤC ......................90 15.1 TÍNH LẶP LẠI VÀ TÍNH TÁI LẬP ................90 15.2 DỮ LIỆU VỀ HIỆU SUẤT LÂM SÀNG ..............90...
Page 69
Giới hạn độ ẩm Bản dịch Thiết bị TonoCare của Keeler được thiết kế và xây dựng theo Chỉ thị 93/42/EEC, Quy định (EU) 2017/745 và Hệ thống Quản lý Chất lượng Thiết bị Y tế ISO 13485. Phân loại: CE / UKCA: Loại IIa...
Page 70
Thiết bị TonoCare của KEELER Các ký hiệu được sử dụng trên bộ điều khiển và màn hình Những ký hiệu này sẽ được sử dụng trên thiết bị và màn hình trong quá trình vận hành. Bộ điều khiển Thiết bị Các ký hiệu trên Màn Mô tả hình Nút On / Standby Đèn Bật / Tắt Đèn LED chiếu sáng (Bật / Chế...
1.1 MỤC ĐÍCH SỬ DỤNG/NGUYÊN TẮC VẬN HÀNH Máy đo nhãn áp Keeler TonoCare là một thiết bị cầm tay hoạt động bằng ắc quy và không tiếp xúc, được sử dụng để đo áp lực nội nhãn (IOP) của mắt người có độ loạn thị dưới Thiết bị...
Vui lòng chú ý rằng thiết bị chỉ đảm bảo hoạt động một cách chính xác và an toàn nếu cả thiết bị và phụ kiện của chúng được cung cấp độc quyền từ Công ty TNHH Keeler. Việc sử dụng các phụ kiện khác có thể khiến thiết bị gây ra mức phát xạ điện từ cao hoặc giảm khả...
Page 73
Để tránh xảy ra ngưng tụ, hãy để thiết bị về lại nhiệt độ phòng trước khi sử dụng. • • Vui lòng dán các nhãn lỗ gắn/treo để che đi các lỗ khoá trừ khi thiết bị TonoCare được treo trên tường. Chỉ gắn/treo thiết bị trên tường theo hướng dẫn của Keeler.
Những yếu tố này được khuyến cáo là cần được xem xét đánh giá trong quá trình đo IOP. Thiết bị Keeler TonoCare được khuyến cáo không nên sử dụng cho các bệnh nhân có mức loạn thị cao (> 3D).
• Tua vít PH1 4.2 CÁC BỘ PHẬN TRONG THÙNG HÀNG Thiết bị TonoCare được cung cấp kèm với: Một Thiết bị cầm tay cùng ắc quy đã lắp sẵn để đo IOP một cách độc lập. • Một Trạm nối để in, xuất dữ liệu và sạc.
4.4 LẮP ĐẶT TẤM GẮN TƯỜNG 1. Cẩn thận lựa chọn vị trí cho Trạm nối của TonoCare sau khi đã xem xét kỹ lưỡng việc đi dây cáp nguồn và vị trí sàng lọc bệnh nhân. Đảm bảo rằng luôn có thể tiếp...
5. SỬ DỤNG THIẾT BỊ TONOCARE Phần này sẽ hướng dẫn người dùng cách diễn giải các điều khiển và chỉ báo trên thiết bị TonoCare và cách thực hiện đo IOP trên bệnh nhân bằng thiết bị. Hãy tự làm quen với các hướng dẫn về cách đo IOP bằng thiết bị TonoCare trước khi sử dụng thiết bị cho bệnh nhân.
Page 78
Thiết bị TonoCare của KEELER Chú ý: Chỉ báo đèn LED trên TonoCare sẽ nhấp nháy khi sạc và duy trì trạng thái đèn khi sạc đầy Chế độ xem đẳng cự từ người dùng và phía bên trái Tựa đầu Thị kính Hình ảnh nhìn từ dưới máy đo nhãn áp Các tiếp điểm sạc Đầu vào nguồn điện Góc nhìn của bệnh nhân...
Thiết bị TonoCare của KEELER Góc nhìn từ phía dưới Đầu vào nguồn điện Giao diện USB – Kết nối máy đo nhãn áp với một PC để có thể tải lên dữ liệu thô. Góc nhìn cho biết bị trí của Thiết bị cầm tay cùng Trạm nối 5.2 SƠ ĐỒ MENU Nhấn nút Menu để mở Menu Phần mềm. Ở trong Menu Phần mềm, sử dụng nút Menu để...
Nếu bạn nghi ngờ rằng máy đo nhãn áp đang chịu bất kỳ tác động nào hoặc bị hơi ẩm xâm nhập thì vui lòng không sử dụng thiết bị. Liên hệ với Keeler hoặc trung tâm bảo dưỡng địa phương của bạn để được tư vấn.
Thiết bị TonoCare của KEELER Phần mềm TonoCare sẽ ghi nhận dữ liệu và phát ra thông báo khi hai dữ liệu liên tiếp chênh nhau 1mmHg, có nghĩa là không cần thêm các lần đo khác. 6.2 CHUẨN BỊ THIẾT BỊ...
Page 82
đã đủ dữ liệu đo (nếu Âm báo được bật trong User Menu Options (Tuỳ chọn Menu Người dùng)). Nếu các dữ liệu đo liên tiếp cách nhau hơn 1 mmHg, thì Keeler đề xuất thực hiện 4 lần đo dữ liệu và lấy kết quả trung bình.
Thiết bị TonoCare của KEELER 13. Nhấn nút OD / OS để chuyển từ mắt trái sang phải và ngược lại. 14. Nhấn và giữ nút OD / OS để xóa toàn bộ dữ liệu đo. 15. Nhấn nút Print (In) sẽ xuất ra một bản in giấy từ máy in được lắp đặt trong Trạm nối.
Page 84
Thiết bị TonoCare của KEELER Quy trình thực hiện CCT của thiết bị TonoCare Obtain Thu được dữ readings for liệu đo cho một either one or hoặc cả hai mắt both eyes Nút OD/ OD/OS Button Menu button Nút Menu Menu button Nút Menu Nhấn nhẹ Short press Nhấn nhẹ Short press Hộp thoại CCT Hộp thoại CCT CCT dialog CCT dialog (danh sách lựa (danh sách lựa...
Chú ý tránh tiếp xúc với lưỡi dao này khi thay cuộn giấy cho máy in hoặc khi xé các bản in từ thiết bị này. Trạm nối của Thiết bị TonoCare có thể được kết nối với ứng dụng Xuất dữ liệu thông qua cổng USB trên máy tính. Dữ liệu đo sau đó có thể được truyền từ Thiết bị cầm tay tới ứng dụng thông qua Trạm nối.
được ủy quyền để thay thế. Trong trường hợp vô tình đánh rơi Thiết bị TonoCare bị rơi, thì trung tâm dịch vụ bảo dưỡng hoặc nhà phân phối có thể kiểm tra xác minh xem thiết bị còn có thể hiệu chuẩn không.
Nếu Thiết bị TonoCare không được sử dụng trong thời gian dài, hãy nhấn công tắc Đẩy On / Off (Bật / Tắt) về ‘Off’ (Tắt) và ngắt kết nối nguồn điện. Sử dụng tấm che bụi để bảo vệ...
11. THÔNG SỐ KỸ THUẬT VÀ ĐỊNH MỨC VỀ ĐIỆN Thiết bị TonoCare của Keeler là một thiết bị điện y học. Thiết bị có yêu cầu đặc biệt về tính tương thích điện từ (EMC). Phần này sẽ mô tả sự phù hợp của nó trong các khía cạnh tương thích điện từ...
Page 89
Không sử dụng các thiết bị liên lạc tần số vô tuyến cầm tay và di động gần bất kỳ bộ phận nào của Thiết bị TonoCare của Keeler, bao gồm cả dây cáp, ở khoảng cách gần hơn khoảng cách khuyến cáo được tính toán từ...
điện từ do các máy phát RF cố định, thì ta cần xem xét khảo sát khu vực điện từ. Nếu từ trường đo được tại vị trí mà Thiết bị TonoCare của Keeler được sử dụng vượt quá mức tuân thủ...
Phích cắm nguồn là các phương tiện cô lập thiết bị với nguồn điện lưới - Đảm bảo luôn có thể tiếp cận với Phích cắm nguồn. Chú ý 1: Nếu kết nối Thiết bị TonoCare với máy tính, thì máy tính phải tuân thủ các yêu cầu EN 60601-1: Chú...
Page 92
Thiết bị TonoCare của KEELER Trạm nối Kích thước của Trạm nối 153 x 155 x 183 mm (Cao x Rộng x Sâu) Trọng lượng của Trạm nối 0,725 Kg Chống giật điện Loại II Xếp hạng IP IPX0 Thiết bị Cấp điện Chế độ chuyển đổi, loại đa phích cắm (110 – 240V) +/- 10% 350-700mA Tuân thủ: EN 60601-1, EN 61000-6-2, EN 61000-6-3...
Thiết bị TonoCare của KEELER 13. PHỤ KIỆN VÀ PHỤ TÙNG Mục Mã bộ phận Đế sạc 2418-P-5002 Tựa đầu 2418-P-7000 Bộ cấp nguồn EP29-32777 Hộp đựng Thiết bị TonoCare 3418-P-7000 Tấm che mặt Máy đo nhãn áp 2415-P-7038 Cuộn giấy máy in 2208-L-7008 14. THÔNG TIN VỀ ĐÓNG GÓI VÀ XỬ LÝ THẢI Xử lý các thiết bị điện và điện tử cũ...
Page 94
15. PHỤ LỤC 15.1 TÍNH LẶP LẠI VÀ TÍNH TÁI LẬP Tính Lặp lại và Tính tái lập của Thiết bị TonoCare được đánh giá bằng cách đo mắt bằng thử nghiệm có kiểm soát sử dụng áp kế. Tính Lặp lại được đo bằng cách sử dụng một thiết bị TonoCare và một chuỗi khoảng 50 giá...
Page 95
Nghiên cứu đã thu được các kết quả đo IOP trên từng mắt đạt tiêu chuẩn bằng Máy đo nhãn áp của TonoCare và máy đo nhãn áp Perkins tiêu chuẩn.
Page 96
đo IOP. Bảng 2 phân loại các chênh lệch tuyệt đối giữa các kết quả đo IOP bằng TonoCare và Perkins AT > 5 mmHg nói chung và trong 3 nhóm phụ IOP. Chênh lệch lớn hơn mức dung sai ±5 mmHg xảy ra ở...
Page 97
Những nhà điều tra đã kết luận rằng không có những chênh lệch có ý nghĩa về mặt lâm sàng ở các số đo IOP giữa các máy đo nhãn áp, và máy đo nhãn áp TonoCare tuân thủ các tiêu chuẩn như đã nêu.
Page 98
电话:021‐61519088 Tel +91 22 4124 8001 Representatives Notified Body 0120 SGS United Kingdom Ltd Keeler Europe Distribution, S.L. Inward Way, Rossmore Business Park Colom, 453, Nau D50 Ellesmere Port, Cheshire, CH65 3EN 08223 Terrassa, Spain United Kingdom Tel +44 (0) 151 350 6666...
Need help?
Do you have a question about the tonocare and is the answer not in the manual?
Questions and answers