Furnace and Water Heater

The Alde central heating and hot water boiler is a
hydronic system that works by circulating hot glycol
fluid through pipes while convectors located along the
outer walls heat the air� As the hot air rises it heats the
walls and surrounding furniture� When the warm air
reaches the ceiling it circulates back down to the floor
and is reheated by the convectors� The built-in water
heater automatically adjusts its power output to match
demand to ensure maximum efficiency operating on
either LPG, 120V or both� The compact design allows
for all connections to be located on the front of the
boiler which allows for easy access and maximizes
usable space�
Both LP Gas and electric heating use hot glycol fluid to
heat the space in the RV� In order to achieve the best
possible results from convected heat, it is important to
allow air to circulate freely� Ensure that the air supply
to the convectors is not obstructed in any way� It is just
as important that cushions or blankets do not interrupt
the flow of air behind backrests and wall cabinets.
The Aldi System requires periodic maintenance;
Maintaining The Heating System on page
NOTICE
The heating system must be filled with a mixture
of water and glycol. Use only high quality ready-
mixed Propylene glycol (with inhibitor) intended
for use in aluminum heating systems. The glycol
must carry the label GRAS (generally recognized
as safe). Alde recommends only using ALDE
brand glycol specifically formulated for the Alde
heating system.

Shower Boost Mode

Before taking a shower it is recommended the "boost"
function be activated 10 minutes prior� This can be
done by pressing the
from the Alde control panels "menu" screen� Turning
ON the boost function will temporarily suspend heat
to the trailer and raise the water temperature� After 30
minutes the system automatically returns to normal
operation� Boost mode can be canceled and the
system returned to normal operation before the 30
minute run time by pressing the
NOTE
The Alde Service App gives you access to
overviews, manuals, and other useful service
information whenever you need service and
support. Download the app at your respective
smart phone app store.
2024 Classic
see
8-19�
button for shower boost
button�

Control Panel

Alde's 3�5" touch screen control panel has been
installed next to the main Multiplex touchscreen panel�
The background lights up when you press the screen
or the MENU button� Settings are automatically saved
after 10 seconds and the control panel reverts back to
standby after 30 seconds of inactivity�
Normal operation of the system will only require a
press of the MENU button to access the settings
menu� On this screen controls are displayed to set the
temperature, turn on shower boost, selecting level 1 or
2 electrical operation, or turning ON gas operation�
For more information on the Alde control panel or for
servicing the system please refer to the supplied Alde
user manual�
NOTE
Prior to setting a heat mode you must first select
electric, gas, or both as the heating method.
NOTE
Follow the instructions provided in your
owner's packet for operation of the control
panel. If warranty service is required, use only
a service location recommended by the furnace
manufacturer or your Airstream dealer.

Microwave Ovens

Refer to the Certified Performance Checkout sheet,
included in your owner's packet, for manufacturer,
model, and serial number information�
Interior