Millivolt Valve Systems - Unpacking And Setup - Ob Burners - Barbara Jean OB24MVN Manual

Outdoor linear fire pit/ outdoor fireplaces
Hide thumbs Also See for OB24MVN:
Table of Contents

Advertisement

OB Burners – Unpacking and Setup – Millivolt Valve Systems
Pilot Assembly is
installed from
bottom of Burner
Tray – but can be
serviced from the
Top.
[Qty 2] 1/2"
DT Screws
Connect Electrode
Wire to Piezo.
Connect On/Off
Switch to TP and
TH Terminals
.
Pilot Opening
Cover
Connect Electrode Wire to
Piezo.
Connect On/Off Switch to
TP and TH Terminals.
STEP 1 (For OB72 & OB96 only):
Connect Burners using [2] 10-24 x
1/2" bolts. Set Cover Clip over joined
burner ends.
Cover Clip
Parts List: OB24 / OB36 / OB48MVN
[1] Burner, c/w [1] Pilot Shield, [2] Ends, [3] Filler Strips
[1] Millivolt Valve System (c/w Orifice Assembly and Pilot Assembly)
[1] Piezo Button Igniter c/w wire and Sparker
[1] On/Off Rocker Switch (Installed on valve)
Orifice
Retainer
[1] Hardware Bag: [8] 1/2" DT Screws, [4] #6 Black Screws
Bracket
[3] Filler Strips (See Below)
[Qty 2] 1/2"
WARNING: Failure to position the parts in accordance with these
DT Screws
diagrams or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
FILLER STRIPS:
Long Flange Up
Short Flange
Down
[Qty 4] 1/2"
DT Screws
to attach
24OB – 10-5/8"
valve to
36OB – 10-5/8" (x 2 for OB72)
appliance
48OB – 10-5/8" (x 2 for OB96)
STEP 2: Insert Orifice(s)
into mixing sleeve(s) and
install bracket(s) with [4]
1/2" DT Screws. Then
insert Pilot Assembly into
one Burner and attach with
[2] 1/2" DT Screws.
Attach Pilot Opening Cover
in the other Burner with [2]
1/2"DT Screws.
Air Shutter = 1/16"- NG
Air Shutter = Full Open- LP
STEP 3: Install Burner with attached Valve System into structure.
For Outdoor Fire Tables (OFT) refer to OFT Burner Installation Instructions page.
For Outdoor Fireplaces (OFP) refer to OFP Burner Installation Instructions page.
For Custom Enclosures refer to Custom Enclosures Section.
NOTE: Filler Strips must be installed before media is placed into burner.
24OB – 23-9/16"
36OB – 35-9/16" (x 2 for OB72)
48OB – 47-9/16" (x 2 for OB96)
36OB – 22-5/8" (x 2 for OB72)
48OB – 34-5/8" (x 2 for OB96)
Parts List: OB72 / OB96MVN
[2] Burners, c/w [2] Pilot Shields, [2] Ends, [6] Filler Strips
[1] Millivolt Valve System (c/w [2] Orifice Assemblies and [1] Pilot
Assembly)
[1] Piezo Button Igniter c/w wire and Sparker
[1] On/Off Rocker Switch (installed on valve)
[1] Pilot Opening Cover
[1] Hardware Bag: [12] 1/2" DT Screws, [8] #6 Black Screws, [2]
10-24 x 1/2" Bolts c/w Star Nuts
[6] Filler Strips
[1] Cover Clip
Install Pilot Assembly and
Orifice Bracket [4 Dt Screws].
24OB – 10-5/8"
11

Advertisement

Table of Contents
loading

Table of Contents