SEC/KP: technical data
SEK/KP
DOOR STATION PROGRAMMING
This section explains how to program the door station functions.
Each function parameter can be edited by input the (Master)
programming code and then an operation code, amongst those
included in the table on the right and finally the new value for
the function.The diagrams on the next pages show in detail the
sequences to input. While inputting the programming sequences
the door station panel will highlight the progress by changing the
backlight colour (white, yellow, green) and by emitting of different
sounds. Each step of programming as well as PIN code storing be-
gins by inputting the Master code (1234), followed by # button. The
panel back light will change to white and two confirmation tones
will be played. Once the Master code has been input, it is possible
to program more operating codes in sequence, without retype the
Master password again. To exit the programming process of the
panel, press the "*" button at any time, the back light colour will
change to the stand-by one. If no button are pressed within 10
seconds, the door panel will automatically exit the programming.
In case of wrong code or value input the door panel will highlight
the state by red backlighting and a dissuasive buzzer sound.
UNLOCK BY USER CODE
Once the user has input the PIN code to release the door (1-12
digits), touch the button "#" to confirm: the keypad's backlight will
light up green, a confirmation tone will sound and the relay will
be activated. The code's digits must be input within a maximum
interval of 10 seconds, otherwise they will be cleared. In case of
inputting a wrong number it is possible to touch the button "*" to
cancel and input the code once again. The lock release function
will be disabled for 60 seconds in case of 10 wrong attempts of
inputting unlock codes, during this time the buzzer will sound
8 times. There are two code groups: only the first group allows
to activate the internal relay while the second group allows the
activation of art. SER01.
Image sensor
Resolution
Video system
Viewing angle
Material
Call ID (default)
Power supply
Consumption
Door lock maximum load
Operating temperature
FUNCTIONS
Reset all settings
Master code
Backlight time
Unlock Time
Unlock Mode
Key Tones
Reset master code
"*" and "#" function
Langauge
Vocal messages volume
Mic gain
SPK volume
Address
Night light level
Not used
Temporary code 1
Temporary code 2
(SER01)
PIN code group 1
PIN code group 2 (SER01)
Mode
Call address
Display scene
Touch sensitivity
Colour CMOS 1/4" sensor
650 TV line
PAL
170°
Die cast
0 (mode 1)
24 Vdc
40 mA stand-by – 380 mA max
12 Vdc / 250 mA max
-10 ÷ +40 °C
CODE
VALUES
00
1234
01
[0 ÷ 9], 1 ÷ 12 digits
02
[00, 10 ÷ 99] sec.
03
[01 ÷ 99] sec.
0 = opened
04
1 = closed
0 = on
05
1 = off
06
1234
0 = normal
07
1 = reverse
08
[0 ÷ 9]
09
[0 ÷ 9]
10
[0 ÷ 9]
11
[0 ÷ 9]
12
[0 ÷ 3]
13
[0 ÷ 5]
14 ÷ 17
18
[0 ÷ 9], 1 ÷ 12 digits
19
[0 ÷ 9], 1 ÷ 12 digits
[0 ÷ 9], 1 ÷ 12 digits
20 ÷ 59
40 codes
[0 ÷ 9], 1 ÷ 12 digits
60 ÷ 99
40 codes
0 = multiway
100
1 = one - way villa kit
[0 ÷ 9]
101
Villa [00 / 16]
Multi [00 - 31]
102
[0 ÷ 1]
103
[0 ÷ 5]
Mi 2528/7
DEFAULT
-
1234
10 sec.
1 sec.
Opened
On
-
Normal
0
5
7
4
0
4
-
-
-
-
One - way
0
0
3
- 19 -