Region Exiting Detection
For certain network cameras, region exiting detection function detects people, vehicles or other
objects which exit from a pre-defined virtual region, and some certain actions can be taken when
the alarm is triggered.
Steps
1. Go to Configuration → Event → Smart Event → Region Exiting .
2. Set Camera.
3. Turn on Enable.
4. Optional: Check Save VCA Picture to save the captured pictures of VCA detection.
5. Set the detection rules and detection areas.
1) Set Arming Area. Up to 4 arming areas are selectable.
2) Adjust Sensitivity. Sensitivity: Range [0-100]. The higher the value is, the more easily the
detection alarm can be triggered.
3) Optional: Set Target Detection as Human or Vehicle to discard alarms which are not triggered
by human body or vehicle.
Note
This function is only available for certain models.
4) Click Draw Area and draw a quadrilateral in the preview window by specifying four vertexes of
the detection region.
6. Set the arming schedule. Refer to Configure Arming Schedule for details.
7. Set the linkage actions. Refer to Configure Alarm Linkage Action for details.
8. Click Apply.

6.4.3 Face Recognition

Face recognition is the function that compares a captured face (in image or video stream) with
those in face picture libraries and returns its identity information if the face is recognized. Based on
facial feature of human being, face recognition first checks if human face exists in the input image
or video stream. If there is a human face, the function compares the face data (such as position,
size, and facial feature) with those in current face picture libraries to identify the person.
Before You Start
Make sure you have configured related parameters on Hik Central Professional or Hik Connect and
disabled Motion and Perimeter Protection.
Note
This function is only available for certain models.