Technical Data; Before Starting The Equipment; Attachment And Operation - Scheppach 5906102901 Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19

6. Technical data

Mains connection
Motor rating
Operating mode
Compressor speed
Pressure vessel capacity
Operating pressure
Theoretical intake capacity
Effective delivery quantity at
1 bar
Protection type
Weight of the unit
Oil (15W 40) l
Max. altitude
(above mean sea level)
The noise emission values were measured in accord-
ance with EN ISO 3744.
Wear hearing protection.
The effects of noise can cause a loss of hearing.
m Warning: Noise can have serious effects on your
health. If the machine noise exceeds 85 dB (A), please
wear suitable hearing protection.
Sound power level L
wA
Sound pressure level L
pA
Uncertainty K
wA/pA
7.

Before starting the equipment

• Before you connect the equipment to the mains sup-
ply make sure that the data on the rating plate are
identical to the mains data.
• Prior to initial commissioning, remove the transport
plug (B) and fill the crank housing with oil as de-
scribed in item 8.4.
• Check the equipment for damage which may have
occurred in transit. Report any damage immediately
to the transport company which was used to deliver
the compressor.
• Install the compressor near the point of consump-
tion.
• Avoid long air lines and supply lines (extension ca-
• Make sure that the intake air is dry and dustfree.
230 V~ 50 Hz
• Do not install the compressor in a damp or wet
2200 W
S1
• The compressor may only be used in suitable rooms
2850 min
-1
50 l
approx. 10 bar
• The compressor is designed to be used in dry
approx. 412 l/min
approx. 294 l/min
• The oil level in the compressor pump has to be
IP32
approx. 41.5 kg
• The compressor may only be used outdoor briefly
approx. 0.25 l
• The compressor must always be kept dry and must
1000 m

8. Attachment and operation

m Important!
You must fully assemble the appliance before using it
for the first time!
You will require the following tools for assembly and
installation:
• 2 x open-ended wrench size 17 mm (not included)
• 2 x open-ended wrench size 14 mm (not included)
91.3 dB(A)
71.2 dB(A)
8.1 Fitting the wheels (Fig. 5)
2.03 dB(A)
• Fit the supplied wheels (11) as shown.
8.2 Fitting the supporting foot (2x) (Fig. 6)
• Fit the supplied supporting foot (2x) as shown.
8.3 Fitting the air filter (2x) (Fig. 7, 8)
• Remove the transportation stop (A) and screw the
www.scheppach.com
bles).
room.
(with good ventilation and an ambient temperature
from +5 °C to 40 °C). There must be no dust, ac-
ids, vapors, explosive gases or inflammable gases
in the room.
rooms. It is prohibited to use the compressor in ar-
eas where work is conducted with sprayed water.
checked before putting the equipment into opera-
tion.
when the ambient conditions are dry.
not be left outdoors after work is complete.
air filter (14) to the equipment.
GB | 25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hc53dc

Table of Contents