Table 4-18 Objects Related To The Trap Notification; From An Error) - Hitachi HF-W6500 60 Manual

Industrial computer
Table of Contents

Advertisement

No.
Object
number
hfwMemFailure
7
hfwMcuFailure
8
No.1: %1 denotes the name of the failed fan.
Nos. 3 and 4: %2 denotes the drive bay number.
Nos. 5 and 7: The memory name that detected the possibility of occurrence or failure at frequent error correction is set to % 3.
No.6: %4 denotes the number of the array with an error. For this equipment, the array number is always 1.
No.8:%5 denotes the name of the RAS MCU where the failure occurred.
Table 4-18 shows a list of the objects related to the trap notification when the
equipment has recovered from an error and a description of those objects. The
enterprise ID for the trap notification when the equipment has recovered from an error
is as follows.
Enterprise ID:
iso.org.dod.internet.private.enterprises.Hitachi.systemAP.
Table 4-18 Objects Related to the Trap Notification (When the Equipment Has Recovered

from an Error)

No.
Object
number
hfwFanRecover
1
hfwTempRecover
2
hfwMemRecover
3
hfwArrayRecover
4
Trap
Description
A failure anticipation
occurs.
8
A RAS MCU failure
occurs.
9
hfwMibTrap.hfwRasRecoverTrap
or
.1.3.6.1.4.1.116.7.45.2
Trap
Description
Recovery from fan
failure
1
Recovery from
abnormal temperature
2
in the chassis
Recovery from
frequent error
6
correction
Recovery from RAID
7
error
4. CHECKING THE HARDWARE STATUS
Object used
memName
memStatus
hfwMemFailMsg
mcuName
mcuStatus
hfwMcuFailMsg
Object used
fanName
Name of the recovered fan
fanStatus
1: Normal
hfwFanStMsg
Revolutions of %1 returned to normal value.
tempName
Internal temperature
tempStatus
1: Normal
hfwTempStMsg
Internal temperature returned to prescribed
value.
memName
Name of the recovered memory slot
memStatus
1: Normal
hfwMemStMsg
In the %2, frequency of the error
correctings deteriorated.
raidIndex
1
Array%3 is restored.
hfwArrayStMsg
4-37
Notification data
Value
Name of the memory slot with failure
anticipation
2: Error (Failure anticipation)
%3 failure might occur.
Name of the RAS MCU that failed.
2: Failure (RAS MCU failure)
%5 is broken.
Notification data
Value
(2/2)