4.4.2 Status codes to be displayed
(1) Hardware status codes
A hardware status code is displayed when an error has occurred in the hardware status
of this equipment. If the hardware status is normal, a hardware status code is not
displayed.
When a hardware status code is displayed, the leftmost LED in the status indication
LEDs is lit.
[If hardware status is normal]
Table 4-9 shows a list of hardware status codes.
No.
Status code
1
11
2
12
3
13
4
21
5
31
6
32
7
33
8
41
9
42
10
4c
11
4d
Nos. 8 through 11: Those status codes are displayed for B and T Model only.
No.11: This code is displayed if media error is configured to be reported as an error.
If multiple failures occur at the same time, the status code with the highest priority (code
with the smallest value in the Priority column in Table 4-9) is displayed. If multiple
failures with the same priority occur at the same time, the status code of the last detected
failure is displayed.
Off

Figure 4-10 Hardware Status Codes

Table 4-9 Hardware Status Codes

PS fan failure
Front fan1 failure
Front fan2 failure
The temperature inside the chassis becomes abnormal.
A failure is anticipated for the drive on drive bay1.
A failure is anticipated for the drive on drive bay2.
A failure is anticipated for the drive on drive bay3.
Drive bay1 is offline. (Include REBUILD)
Drive bay2 is offline. (Include REBUILD)
RAID is in an unknown status.
Media error on RAID
4-19
4. CHECKING THE HARDWARE STATUS
[If hardware status is not normal]