AER DMEV 100 SELV
COD. 5.671.084.338
08/11/2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AER DMEV 100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vortice AER DMEV 100

  • Page 1 Instruction booklet AER DMEV 100 AER DMEV 100 SELV COD. 5.671.084.338 08/11/2023...
  • Page 2: Table Of Contents

    3 Compliance ........................4 4 Safety/Warnings .......................5 5 Installation types ......................6 6 Mounting and wiring diagrams ..................6 7 Supply box mounting and wiring diagram (AER DMEV 100 SELV) ......6 8 Maintenance and cleaning ....................6 9 Operation ..........................7 Minimum continuous speed ......................... 7 Intermediate speed ..........................
  • Page 3: General Informations

    Before installing and using the appliance, read the warnings in this manual carefully VORTICE S.p.A. cannot assume any responsibility for damage to property or personal injury resulting from failure to abide by the instructions given in this booklet. Following these instructions will ensure a long service life and overall electrical and mechanical reliability.
  • Page 4: Product Description

    • Power supply 220-240V~ 50/60Hz ‘AER DMEV 100 SELV’ model The AER DMEV 100 unit is also available in the SELV version, with separate power supply box (Fig.19). Compliance - These appliances are designed for use in residential and commercial properties.
  • Page 5: Safety/Warnings

    - The appliance must expel the air outside through its own duct - If the appliance does not function correctly or develops a fault, contact a VORTICE authorised Technical Support Centre without delay. Ensure that only genuine original VORTICE spares are used for any repairs.
  • Page 6: Installation Types

    – it is needed to clean the external parts of the product. Installation types Refer to fig. 1. Mounting and wiring diagrams Figg. 2÷32. Supply box mounting and wiring diagram (AER DMEV 100 SELV) Figg. 20÷32. Maintenance and cleaning Figg. 33÷37.
  • Page 7: Operation

    AER DMEV 100 / AER DMEV 100 SELV Operation • Upon power-up, the unit runs at the minimum continuous speed. • If humidistat or timer is activated, the unit runs at the intermediate speed. • If the external switch is activated, the unit runs at the maximum speed.
  • Page 8: Constant Flow

    AER DMEV 100 / AER DMEV 100 SELV DIP SWITCH A min speed intermediate speed max speed installation default through-wall through-wall through-wall through-wall through-wall through-wall through-wall through-wall in-room in-room in-room in-room in-room in-room in-room in-room Constant flow DIP SWITCH B...
  • Page 9: Run-On Timer

    AER DMEV 100 / AER DMEV 100 SELV Run-on timer The unit is equipped with a run-on timer. When the external switch is turned off, the unit continues to run at the intermediate speed for a period of time defined as follows: •...
  • Page 10 INSTALLATION wall ceiling ducted direct exhausting MOUNTING AND WIRING DIAGRAM AER DMEV 100 AER DMEV 100 SELV...
  • Page 11 click!
  • Page 12 SURFACE CABLE Type and specifications of the cables that can be used: H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm (for installation without external boost switch). 3 X 0,5 ÷ 1,5 mm (for installation with an external boost switch). 4xØ5mm ød d ø10mm...
  • Page 13 PLEASE REFER WIRING DIAGRAMS AT FIG.14A / 14B FOR THE CORRECT WIRING. RECESSED CABLE ENTRY Type and specifications of the cables that can be used: H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm (for installation without external boost switch). 3 X 0,5 ÷...
  • Page 14 AER DMEV 100 Power Unit AER DMEV 100 SELV ATTENTION: WHEN WIRING TO THE PCB TERMINALS, DO NOT OVERTIGHTEN THE SCREWS: MAXIMUM TORQUE 0,15 NM. THE UNIT IS PROVIDED WITH AN INTEGRAL PULL-CORD TO SELECT THE BOOST SPEED. IN THIS CONFIGURATION THE SWITCHED LIVE TERMINAL CONNECTION IS NOT...
  • Page 15 MOUNTING AND WIRING DIAGRAM SELV POWER SUPPLY UNIT...
  • Page 16 4xØ5mm SURFACE CABLE Type and specifications of the cables that can be used: H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm (for installation without external boost switch). 3 X 0,5 ÷ 1,5 mm (for installation with an external boost switch).
  • Page 17 RECESSED CABLE ENTRY Type and specifications of the cables that can be used: H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm (for installation without external boost switch). 3 X 0,5 ÷ 1,5 mm (for installation with an external boost switch).
  • Page 19 MAINTENANCE / CLEANING...
  • Page 24 VORTICE S.p.A. se réserve le droit d’apporter toutes les variations afi n d’améliorer ses produits en cours de commercialisation. VORTICE S.p.A. behält sich vor, alle eventuellen Verbesserungsänderungen an den Produkten des Verkaufsangebots vorzunehmen. VORTICE S.p.A. se reserva el derecho a hacer cambios en los productos para su mejora en cualquier momento sin previo aviso. VORTICE S.p.A.