Lenovo ThinkSystem SR250 V3 Reference page 64

Hide thumbs Also See for ThinkSystem SR250 V3:
Table of Contents

Advertisement

2. If no problem is observed on the DIMM connectors or the problem persists, replace the DIMM
identified by LightPath and/or event log entry.
3. If problem recurs on the same DIMM connector, replace the other DIMMs on the same memory
channel.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. If problem recurs on the same DIMM connector, inspect connector for damage. If damage found or
problem persists, collect Service Data log.
6. Contact Lenovo Support.
• FQXSPMA0012M: An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0146
User Action:
Complete the following steps until the problem is solved:
1. Check the event log of XClarity Controller (XCC) for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and arei n place,clean,
and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If the problem remains and no other DIMMs have the same indication, replace the DIMM.
• FQXSPMA0022I: Post Package Repair Success for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
This message is for the use case when an implementation has detected that Memory double chip sparing
has been initiated.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0140
User Action:
Information only; no action is required.
• FQXSPMA0023I: Post Package Repair Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
This message is for the use case when an implementation has detected that Memory double chip sparing
has been initiated.
Severity: Info
Serviceable: No
60
ThinkSystem SR250 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

7dcl7dcm

Table of Contents