Lenovo ThinkSystem SR250 V3 Reference page 145

Hide thumbs Also See for ThinkSystem SR250 V3:
Table of Contents

Advertisement

User Action:
Information only; no action is required.
• FQXSPUP4002I: Flash of [arg1] from [arg2] failed for user [arg3].
This message is for the use case where a user has not flashed the firmware component from the interface
and IP address due to a failure.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0036
User Action:
Information only; no action is required.
• FQXSPUP4003I: [arg1] firmware mismatch internal to system [arg2]. Please attempt to flash the
[arg3] firmware.
This message is for the use case where a specific type of firmware mismatch has been detected.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0042
User Action:
Complete the following steps until the problem is solved:
1. AC cycle the system.
2. Reflash XCC/BMC firmware to the latest version.
3. NOTE: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. If problem persists, collect Service Data log.
5. Contact Lenovo Support.
• FQXSPUP4004I: XCC firmware mismatch between nodes/servers [arg1] and [arg2]. Please attempt
to flash the XCC firmware to the same level on all nodes/servers.
A mismatch of XCC firmware has been detected between nodes/servers
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0132
User Action:
Complete the following steps until the problem is solved:
1. Reflash XCC/BMC firmware to the latest version on all servers.
.
Chapter 2
XClarity Controller events
141

Advertisement

Table of Contents
loading

This manual is also suitable for:

7dcl7dcm

Table of Contents