Lenovo ThinkSystem SR250 V3 Reference page 190

Hide thumbs Also See for ThinkSystem SR250 V3:
Table of Contents

Advertisement

Information only; no action is required.
• FQXPMUP0102I: Start to update window driver
Severity: Info
User Action:
Information only; no action is required.
• FQXPMUP0103I: Start to update linux driver
Severity: Info
User Action:
Information only; no action is required.
• FQXPMUP0104I: Start to update UEFI
Severity: Info
User Action:
Information only; no action is required.
• FQXPMUP0105I: Start to update BMC
Severity: Info
User Action:
Information only; no action is required.
• FQXPMUP0106I: Successfully updated the firmware
Severity: Info
User Action:
Information only; no action is required.
• FQXPMUP0201M: BMC communication failed: EMMC2USB mount failure. Failed to update the
firmware
Severity: Error
User Action:
1. Restart BMC via supported method and BMC setting via uEFI setup or "Restart Management
Controller" in BMC web UI. Then, reboot the system.
2. If the problem persists, reflash the BMC firmware.
3. If the problem persists, perform AC reset or virtual reseat.
Note: When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
4. If the problem persists, try a different Lenovo tool to perform the update (eg. XClarity Administrator,
XClarity Controller, or XClarity Essential OneCLI).
5. If the problem persists, contact technical support.
• FQXPMUP0202M: Transfer the update package error. Failed to update the firmware
Severity: Error
User Action:
186
ThinkSystem SR250 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

7dcl7dcm

Table of Contents