BioSense Series Network Video Recorder
7.4.3.8.
Line Crossing
The purpose of this page is to configure the relevant parameters, so that more than the proportion of
moving objects, across the set of test lines, the virtual alarm immediately alarm line. The following
describes the main parameters of the page setting method.
Channel: Select the channel.
Detect Mode: Divided into front-end and local, two models to the actual capacity of the product
subject, select the front-end mode requires front-end access to IPC support, select the local mode
requires the device support.
Enable: Set whether to enable zone detection function.
Display when Preview: Set whether to display the set rules and test results in the preview
interface.
Arming: That is, set the deployment time, the default is all-day deployment.
Linkage: You can enter the linkage configuration page when the alarm is triggered, and perform
the linkage configuration operation.
Detection Area: Filter out less than the proportion of the set of moving objects.
Detection Type: Set the detection object to be human or vehicle, and an alarm will be triggered when
the object detected in the area is the set value.
ExchangeA/B: On the screen with the mouse to draw the test line, a key exchange A/B.
Advanced Setting:
Detection Type: There are two types: "A > B Alarm" and "A <-> B Alarm"
Ratio: moving objects in the screen than the size of the set when the size can be used as a "target".
According to the above settings, in this picture of a channel, accounted for more than 30 of the moving
object, across the detection line from A region to B area, triggered area detection alarm, as shown in
P a g e
| 52
Figure 7.33 Line Crossing