ZKTeco BioSense Series User Manual page 46

Table of Contents

Advertisement

BioSense Series Network Video Recorder
The purpose of this page is to configure the relevant parameters so that the target count alarm occurs
when a moving object whose proportion is larger strides the set detection line to obtain the number set
by the detection rules, as shown in Figure 7.24. The following describes the parameters of the pages on
the set method.
Channel Select: Select the channel.
Detect Mode: Divided into front-end and local, the two models to the actual capacity of the product
subject, selecting the front-end mode requires front-end access to IPC support, selecting the local
model requires equipment support.
Enable: Check to enable the target count.
Display when Preview: When enabled, you can see the detection line and the statistical result
in the preview interface.
Detection lines: Each screen can be set up to four detection lines, directly on the screen drag the
left mouse button to draw the line, release the left button, right-click to complete the drawing
line, the completion of the detection line on both sides were AB Area, the upper side will display the
statistical results.
Detection Type: Set the detection object to be human or vehicle, and an alarm will be triggered
when the object detected in the area is the set value.
Advanced Setting:
A > B: Acquiesce is A area to B area to increase counting, A / B area location on both sides of
detection line can be exchanged.
B > A: "Increment Count" or "Flow Count Result = 'A-> Count of B' + 'B-> Count of A'", "Count Down" >
Count of B '-' B-> Count of A '', 'Ignore' or 'Count of flow statistics '='.
Ratio: Only when size of Moving objects in the screen is larger than the size of the set can it
used as a "target", when setting the center of the screen will appear a yellow dotted rectangle
frame as a reference.
Enable Flow Statistics: Enable statistics, you can set the "Flow Statistics interval and Alarm
threshold".
Flow Statistics Interval(second): Set the counting time interval. When the counting time exceeds
the time interval set, the flow counter will reset and enter next counting period automatically.
Flow Alarm Threshold Value: Set the upper count limit. When the value exceeds the set value, the
system will automatically trigger the alarm.
Enable Total Quantity Statistics: Enable or disable the Total quantity function.
Statistical Time Quantum: Set the effective time period for the day's total counter.
Total Quantity Alarm Threshold Value: Set the upper limit of the total flow on a day. When the
value exceeds the set value, the system will automatically trigger the alarm.
Arming: That is, set the deployment time, the default is all-day deployment.
Linkage: You can enter the linkage configuration page when the alarm is triggered, and perform
the linkage configuration operation.
Delete: Click to clear the screen to set the history setting line.
P a g e
| 46
Copyright©2023 ZKTECO CO., LTD. All rights reserved.
User Manual
be

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z8516neqZ8504neq-4pZ8508neqZ8504neq

Table of Contents