Operation - Hama Premium Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
• We recommend installing the measuring station securely on
an outdoor wall (C6).
• Install an anchor, screw, nail, etc. in the wall of your choice.

6. Operation

Note – Input
• Hold the
button (B4) or the
values faster.
6.1 Connection to the measuring station
• After you insert the batteries, the base station automatically
searches for a connection to the measuring station and
performs initial setup.
Note
• Initial setup takes approximately 3 minutes.
• During the connection attempt, the radio symbol on the
measuring station (A12) will ash.
• Do not press any buttons during setup. Otherwise, values
may not be transmitted correctly and there is a risk of
value errors and inaccuracies.
• The setup process is completed when the indoor and
outdoor measurement data (A1/A2/A8/A10) is displayed.
• If the base station still does not receive a signal from the
measuring station, press and hold the
approx. 3 seconds to start the manual search for the signal.
6.2 Automatic setting using the DCF signal
• After the rst time the base station is switched on and
successful transmission is established between the
base station and the measuring station, the clock will
automatically search for a DCF signal. During the search, the
wireless symbol (A13) will ash.
• When the wireless signal is received, the date and time are
automatically set.
Note – Time settings
• The search process takes about 7 minutes. If the search fails,
it ends and is repeated at the next clock hour.
• In the meantime you can, however, set the time and the date
manually.
• The clock automatically continues to search for the DCF signal
on a daily basis (between 1:00 a.m. and 5:00 a.m.). If the
signal is received successfully, the manually set time and date
are overwritten.
7. Care and Maintenance
• Only clean this product with a slightly damp, lint-free cloth
and do not use aggressive cleaning agents.
• Make sure that water does not get into the product.
Note
Disconnect the device from the power supply before cleaning
it or if it is not going to be used for a long period of time.
7
button (B5) to select the
button (B5) for
8. Warranty Disclaimer
Hama GmbH & Co KG assumes no liability and provides no
warranty for damage resulting from improper installation/
mounting, improper use of the product or from failure to
observe the operating instructions and/or safety notes.
9. Technical Data
Speci cations in accordance with
Regulation (EU) 2019/1782
Manufacturer's name or
trade mark, commercial
registration number and
address
Model identi er
Input voltage
Input AC frequency
Output voltage /
Output current /
Output power
Average active e ciency
E ciency at low load (10 %)
No-load power consumption
Base station
3.0 V
2 x AA batteries
Power supply unit:
Power supply
In: 100-240 V
max. 0.3 A, 50/60 Hz
Out: 5.0 V
1200 mA
Measuring range
-5°C – +50°C /
Temperature (°C)
23°F – +122°F
Humidity
20% – 95%
Max. number of
measuring stations
Range
10. Declaration of Conformity
Hereby, Hama GmbH & Co KG declares that the radio
equipment type [00186380] is in compliance with
Directive 2014/53/EU. The full text of the EU declaration
of conformity is available at the following internet address:
www.hama.com -> 00186380 -> Downloads.
Frequency band(s)
Maximum radio-frequency
power transmitted
Hama, HRA12159,
Dresdner Str. 9,
86653 Monheim
HX075-0501200-AG-001
100 – 240 V
50 / 60 Hz
5.0 V DC /
1.2 A /
6.0 W
76.0 %
70.1 %
0.10 W
Measuring station
3.0 V
2 x AA batteries
max.
-20°C – +60°C /
-4°F – +140°F
20% – 95%
3
60 m
433 MHz
38.9 nW

Advertisement

Table of Contents
loading

This manual is also suitable for:

00186380

Table of Contents