Disturbance
There will be no detergent
pumped out.
Water doesn't come in.
Detergent won't work
washed in.
Repeated application
sling.
Change program duration
changes during the
washing process.
Water is not visible
in the drum
bar.
Drum jerks
Program start.
Cause and troubleshooting
Pump cover is not screwed in completely.
Make sure the pump cover is screwed into the device
until it stops. The handle of the pump cover must be
vertical.
Start/Pauze / Départ/Breakwas not pressed.
PressStart/Pauze / Départ/Break.
Filters in the water inlet are blocked.
Clean the sieves in the water inlet.
Faucet is closed.
Open the faucet.
Water inlet hose is kinked or pinched.
Make sure the water inlet hose is not kinked or
pinched.
Unbalance control system compensates for unbalance by
distributing the laundry several times.
No error - no action necessary.
A notice:When loading, place large and small items of
laundry together in the drum. Different sized items of
laundry are distributed better when spinning.
Program flow is electronically optimized. This can lead
to a change in the program duration.
No error - no action necessary.
Unbalance control system compensates for unbalance by
distributing the laundry several times.
No error - no action necessary.
A notice:When loading, place large and small items of
laundry together in the drum. Different sized items of
laundry are distributed better when spinning.
Foam control system switches on a rinse cycle if foam
formation is too high.
No error - no action necessary.
Water is below the visible range.
No error - no action necessary.
Do not add additional water to the device during
operation.
The cause is an internal engine test.
No error - no action necessary.