float: SunSpec Inverter Model 111, 112, 113 or 211, 212, 213.
int + SF: SunSpec Inverter Model 101, 102, 103 or 201, 202, 203.
"Meter address"
Inverter control via Modbus
If this option is activated, the inverter is controlled via Modbus.
Inverter control includes the following functions:
-
-
-
-

Remote control

Remote control
The grid operator/energy supplier can influence the output power of the inverter
by means of remote control. The prerequisite for this is for the inverter to have
an active internet connection.
Parameter
Remote control
Allow remote
control for reg-
ulatory pur-
poses (Techni-
cian)
Allow remote
control for Vir-
tual Power
Plants (Cus-
tomer)
*) Cloud Control
A virtual power plant is an interconnection of several power plant operators to
form a network. This network can be controlled via the cloud over the internet.
The inverter must have an active internet connection for this. System data is
transmitted.
84
On/Off
Power reduction
Specification of a constant power factor (cos phi)
Specification of a constant reactive power value
and
Profiles
Value range
Off
On
Deactivated/
Activated
Deactivated/
Activated
Description
Remote control of the inverter is deactiv-
ated.
Remote control of the inverter is activ-
ated.
The function
Allow remote control for
regulatory purposes
may be mandatory
for proper operation of the system. *)
Allow remote control for regulatory
If the
purposes
function is enabled (technician
access required), the
Allow remote con-
trol for Virtual Power Plants
automatically enabled and cannot be dis-
abled. *)
function is