Follow these recommendations for copper data cabling in high electrical noise
environments:
RUGGEDCOM RX1512
Equipment Manual, 10/2023, C79000-G8976-1057-25
1.5.2 Gigabit Ethernet 1000Base-TX Cabling Recommendations
Cabling
1000Base-
TX Compliant
> 6
Yes
Data cable lengths should be as short as possible, preferably 3 m (10
ft) in length. Copper data cables should not be used for inter-building
communications.
Power and data cables should not be run in parallel for long distances, and
should be installed in separate conduits. Power and data cables should intersect
at 90° angles when necessary to reduce inductive coupling.
Required Action
Connector and wiring standards to be determined.