Download Print this page

Access Doors - Viking VGSB152T Brochure & Specs

Outdoor products
Hide thumbs Also See for VGSB152T:

Advertisement

4574_Viking_Outdoor_Brochure 9-07
10/15/07
10:10 AM
Basic specifications - Wok/cooker
Description
Overall Width
26 1/4" (66.7 cm)
Overall Height From Bottom
11 3/4" (29.8 cm) to cooking surface
Overall Depth From Rear
32 3/4" (83.2 cm) to end of knobs
Cutout Width
24 3/4" (62.9 cm)
Cutout Height
10 1/4" (26.0 cm)
Cutout Depth
27 3/8" (69.5 cm) minimum
27 7/8" (70.8 cm) maximum
Gas Requirements
Natural: standard residential 1/2" (1.3 cm) ID gas service line
LP/Propane: standard residential 1/2" (1.3 cm) ID gas service line or equipped with high-capacity
hose/regulator for connection to standard 20 lb. LP/Propane cylinder with a Type 1, QCC-1
connector. Unit must be ordered Natural or LP/Propane – unit is not field-convertible.
Maximum Amp Usage
.08 amps
Burner Rating
27,500 BTU NAT./27,500 BTU LP/Propane
Approximate
160 lb. (72.0 kg)
Shipping Weight
Warming drawers/Storage drawers
E L E C T R I C 2 7 " , 3 0 " , A N D 3 6 " W I D E W A R M I N G / S T O R A G E D R A W E R S
Description
VEWD173T/SD170T
Overall Width
26 1/2" (67.3 cm)
Overall Height
10" (25.4 cm)
Overall Depth
24 5/8" (62.5 cm) to front edge of trim, 26 3/4" (67.9 cm) to end of handle bracket,
from Rear
50 3/8" (128.0 cm) with door open
Cutout Width
25" (63.5 cm)
Cutout Height
9 1/4" (23.5 cm)
Cutout Depth
23 3/8" (59.4 cm) minimum
Electrical Requirements
120VAC/60Hz – hard wire direct with separate 15-amp minimum 2-wire with ground circuit
Maximum Amp Usage
3.6 amps/425 watts
Interior Dimensions
Width – 17 1/4" (43.8 cm)
Height – 6" (15.2 cm)
Depth – 22 3/4" (57.8 cm)
Approximate
80 lb. (36.0 kg)
Shipping Weight
Page 41
G A S 2 4 " W I D E W O K / C O O K E R
VGWT241T
VEWD103T/SD100T
VEWD163T/SD160T
29 1/2" (74.9 cm)
35 1/4" (89.5 cm)
28" (71.1 cm)
33 3/4" (85.7 cm)
3.8 amps/450 watts
4.6 amps/550 watts
Width – 20 1/2" (52.1 cm)
Width – 25" (63.5 cm)
Height – 6" (15.2 cm)
Height – 6" (15.2 cm)
Depth – 22 3/4" (57.8 cm)
Depth – 22 3/4" (57.8 cm)
90 lb. (40.5 kg)
110 lb. (49.5 kg)
40

Access doors

D O U B L E A N D S I N G L E A C C E S S D O O R S
Description
AD2820T
Overall Width
28 1/4" (71.8 cm) minimum
(including notches)
30 1/4" (76.8 cm) maximum
Overall Height
20 1/4" (51.4 cm) minimum
(opening only)
20 1/2" (52.1 cm) maximum
Outdoor hoods
An interior- or exterior-power ventilator kit must be purchased for installation with all hoods.
3 6 " , 4 8 " , A N D 6 0 " W I D E
Recommended Ventilator Kits
Models
Number
Number
of Lights
of Filters
Interior-Power
Exterior-Power
18" HIGH WALL HOOD CANOPY – 27" DEEP
VWH3678T-36"W
2
2
VIV1200
VEV1200/VEV1500
VWH4878T-48"W
3
3
VIV1200
VEV1200/VEV1500
VWH6078T-60"W
4
4
VIV1200
VEV1200/VEV1500
Ventilator kits
V E N T I L A T O R K I T S
Interior Ventilators
Description
VIV1200
Approximate CFM
1
1,200
Recommended Duct Size
S E E
H O O D
Maximum Duct Run
2
50 ft. (15.2 m)
Maximum Amps
S E E
H O O D
Please note: Maximum amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired with 2-wire ground. All ventilator kits use 120VAC/60Hz
Proper installation is extremely important to ensure maximum performance from any ventilation product.
1. All CFMs stated based on tests with .1 static pressure; without applying static pressure (some brands consciously do not), CFM could be greatly overstated.
2. Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer.
• Straight runs and gradual turns are best; for example, each 90-degree elbow is equal to 5-10 feet (1.52-3.05 m) of straight run.
• Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
• Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
• Check with a qualified and trained installer or local codes for makeup air requirements, if any.
41
AD1620T
16 1/4" (41.3 cm) minimum
18 1/4" (46.4 cm) maximum
W A L L H O O D S
Recommended Duct Size
Maximum Amps
Interior
Exterior
Interior
Exterior
10"
10"/10"
8.7
6.1/6.8
10"
10"
11.5
8.8/9.5
10"
10"
11.5
8.8/9.5
Exterior Ventilators
VEV1200
VEV1500
1,200
1,500
S P E C I F I C A T I O N S
50 ft. (15.2 m)
75 ft. (22.8 m)
S P E C I F I C A T I O N S

Advertisement

loading